Leuze it 3820 Скачать руководство пользователя страница 2

IT 3820/3820i - 06

2014/07

Specifications

Reading field

Electrical data

IT 3820

ST 2020

Operating voltage U

B

3.7VDC internal battery

9VDC

Power consumption

max. 8W @ 9VDC

Li-ion battery

Capacity

2.000mAh

Max. number of scans

57.000

Max. operating time

16h at 1scan/s

Charging time at 9VDC

4h for complete charge following complete discharge

RF data transmission

Frequency

2.4 … 2.4835GHz (ISM band)
Frequency hopping, Bluetooth ® V1.2, Class 2

Typ. Range

10m

Transmission speed

720kBit/s

Interfaces 

Interface type

TTL-RS 232, PS/2 and USB

Trigger

via button or serial command

Code types 

Bar codes

2/5 Interleaved, Code 39, Code 128, Code 93, Codabar, UPC/EAN, 
RSS, Codablock 

Optical data

Optical system

3648 linear imager

Contrast

20% (black/white)

Light source

integrated diffuse LED 630nm

Read distance

25 … 610mm (UPC 100%)

Read angle

omnidirectional, various tilt and rotational angles up to 65°

Mechanical data

IT 3820

IT 3820i

ST 2020

Housing

UL94V0 grade

Weight

261g

72g

250g (without cable)

Dimensions

157x135x81mm

157x135x81mm

79x142x109mm

Shock resistance

50 falls from a height 
of 1.8m

50 falls from a height 
of 2m 

50 falls from a height 
of 1m

Environmental data

Ambient temp. (operation)

0°C … +50°C

-10°C … +50°C

0°C … +50°C

Ambient temp. (storage)

-40°C … +60°C

-40°C … +70°C

-40°C … +60°C

Relative air humidity

0 … 95% 
(non-condensing)

0 … 95% 
(non-condensing)

0 … 95% 
(non-condensing)

Light source

exempt group (in acc. with EN 62471)

Protection  class

IP 41

IP 54

IP 41

Certifications

IEC 60950-1 (US-19800-UL)

IT 3820 SR

Module or cell

from

to

Code 39

5mil / 0.127mm

105mm

230mm

Code 39

7.5mil / 0.19mm

95mm

360mm

Code 39

10mil / 0.25mm

55mm

465mm

Code 39

13mil / 0.33mm

25mm

610mm

UPC bar code

13mil / 0.33mm

25mm

610mm

Code 39

20mil / 0.50mm

25mm

940mm

Code 39

55mil / 1.40mm

102mm

1120mm

Order guide

Hand-held scanner for barcodes (standard range)

Part No.

IT 3820 SR 0C0BE

IT 3820 SR with RS 232/USB/PS/2 interface

501 06242

IT 3820i SR E 

IT 3820i SR with RS 232/USB/PS/2 interface

501 10471

Base station for Bluetooth transmission

Part No.

ST 2020-5BE 

ST 2020 with RS 232/USB/PS/2 interface 

(without cable)

501 10663

Tables

Diagrams

Remarks

Ergonomically shaped hand-
held scanner with integrated 
decoder for barcodes

Data transmission via config-
urable RS 232 interface. 

Or keyboard-wedge opera-
tion via PS/2 or USB inter-
face.

For a functional unit, an 
IT 3820 hand-held scanner 
and a ST 2020 base station 
as well as a power supply 
unit and corresponding cable 
must be ordered.

Bluetooth is a trademark owned by 
Bluetooth SIG, Inc., U.S.A. and 
licensed to Hand-Held Products

Operate in accordance with
intended use!

The product may only be put into 

operation by competent persons.

Only use the product in accor-

dance with the intended use.

IT 3820/3820i

Содержание it 3820

Страница 1: ...4586 PS 2 cable for IT 4xxx Part No 501 03409 USB cable for IT 4xxx Part No 501 03404 Power supply unit for IT 4x2x Part No 501 03989 IT 3820 IT 3820i IP 41 IP 41 IP 54 Dimensioned drawing Electrical...

Страница 2: ...0 C 60 C Relative air humidity 0 95 non condensing 0 95 non condensing 0 95 non condensing Light source exempt group in acc with EN 62471 Protection class IP 41 IP 54 IP 41 Certifications IEC 60950 1...

Страница 3: ...er A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data a...

Страница 4: ...t in trigger button Configuration for the Leuze standard protocol To set the Leuze standard protocol you must first reset the scanner to factory settings and then individually define each of the trans...

Страница 5: ...nd the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacent barcode The IT 3820 is set to the following transmission parameters RS 232 transmission with 115 200 baud 8 data...

Страница 6: ...ble KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the...

Страница 7: ...in assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the IT 3820 to the serial PC interface 3 Scan th...

Страница 8: ...on ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 409 PS 2 cable Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the ST 2020 base sta tion between the keyboa...

Страница 9: ...n be processed further in all standard programs required parts 1x 501 06 242 IT 3820 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedu...

Страница 10: ...20 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedure 1 Connect the cable for the ST 2020 base station to a free USB port 2 The scann...

Отзывы: