IT 1452g - 01

2015/09

Connecting the IT 1452g to the PS/2 interface

The operation of the hand-held scanner in keyboard emulation mode is described in this section. With this operating mode, a PC 
keyboard is emulated. The read data are written directly into the currently activated program. The data can thereby be further 
processed in all standard programs.

Required parts:

1x

IT 1452g 1D-2 

1x

50130499

Base for IT 1452 base sta-

tion

1x

50114525

Power supply unit

1x 

50114519 KB 

PS2-1 

IT 1902

Procedure:

1.

Switch off the PC.

2.

Disconnect the keyboard.

3.

Connect the cable for the base station 
between the keyboard and the PC.

4.

Switch the PC back on.

5.

Scan the 2D code shown below.

6.

Return the hand-held scanner to the base sta-
tion to apply the settings. This procedure is 
concluded with acoustic confirmation signals.

Notice!

 

To charge the hand-held scanner, the 
power supply unit must be plugged in 
and the hand-held scanner placed in 
the base station.

Disconnect

IT 1452g

Содержание it 1452g

Страница 1: ...0114521 USB helix cable 5m Part no 50114523 Power supply unit Part no 50114525 UL US C LISTED IP IP 42 42 Dimensioned drawing 62 62 82 82 173 173 Hand held scanner IT 1452g 1D 2 with Bluetooth Bluetoo...

Страница 2: ...ons 173x82x62mm 101x131x81mm Shock resistance 30 falls from a height of 1 5m 50 falls from a height of 1m Environmental data Ambient temp operation 0 C 50 C 0 C 50 C Ambient temp storage 40 C 70 C 40...

Страница 3: ...pulling the trigger A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an acoustic signal to confirm that the label has been read if n...

Страница 4: ...COM port emulation only The command is to be sent at the set baud rate parity and data and stop bits The command for activation is SYN T CR ASCII decimal values 022 084 013 To cancel read readiness se...

Страница 5: ...n the computer 3 and to the base station 2 3 Plug one end of the power supply unit cable into the base station 4 and the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacen...

Страница 6: ...T Procedure 1 Insert the KB JST HS 300 cable into the MA 2xxi 2 Connect the interface cable to cable KB JST HS 300 Connect the interface cable and the power supply unit to the base station see Con nec...

Страница 7: ...ield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the...

Страница 8: ...D 2 1x 50130499 Base for IT 1452 base sta tion 1x 50114525 Power supply unit 1x 50114519 KB PS2 1 IT 1902 Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the base stati...

Страница 9: ...he data can therefore be further processed in all standard programs Required parts 1x IT 1452g 1D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x...

Страница 10: ...D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x 3m straight or 1x 50114523 KB USB 2 IT190x 5m spiral Procedure 1 Install the USB serial driver c...

Отзывы: