Leuze it 1452g Скачать руководство пользователя страница 4

IT 1452g - 01

2015/09

Resetting the IT 1452g to factory settings

To reset all parameters to factory settings, scan the adjacent 
bar code. 

Attention!

 

All settings are lost!!!

Return the hand-held scanner to the base station to apply the settings. This procedure is concluded with acoustic confirmation 
signals.

You may then continue making settings or operation of the device.

Trigger

To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation 
only). The command is to be sent at the set baud rate, parity, and data and stop bits. 

The command for activation is: 

SYN T CR

 

ASCII decimal values: 022; 084; 013

To cancel read readiness, send a deactivation. 

The command for deactivation is: 

SYN U CR

ASCII decimal values: 022; 085; 013

Following a successful read operation, the hand-held scanner deactivates itself.

The second option is activation via the built-in trigger button.

Configuration for the Leuze standard protocol

Scan the adjacent 2D-code. 
The hand-held scanner is set to the following transmission parameters: 
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, 
postfixes <CR><LF>.

IT 1452g

Содержание it 1452g

Страница 1: ...0114521 USB helix cable 5m Part no 50114523 Power supply unit Part no 50114525 UL US C LISTED IP IP 42 42 Dimensioned drawing 62 62 82 82 173 173 Hand held scanner IT 1452g 1D 2 with Bluetooth Bluetoo...

Страница 2: ...ons 173x82x62mm 101x131x81mm Shock resistance 30 falls from a height of 1 5m 50 falls from a height of 1m Environmental data Ambient temp operation 0 C 50 C 0 C 50 C Ambient temp storage 40 C 70 C 40...

Страница 3: ...pulling the trigger A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an acoustic signal to confirm that the label has been read if n...

Страница 4: ...COM port emulation only The command is to be sent at the set baud rate parity and data and stop bits The command for activation is SYN T CR ASCII decimal values 022 084 013 To cancel read readiness se...

Страница 5: ...n the computer 3 and to the base station 2 3 Plug one end of the power supply unit cable into the base station 4 and the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacen...

Страница 6: ...T Procedure 1 Insert the KB JST HS 300 cable into the MA 2xxi 2 Connect the interface cable to cable KB JST HS 300 Connect the interface cable and the power supply unit to the base station see Con nec...

Страница 7: ...ield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the...

Страница 8: ...D 2 1x 50130499 Base for IT 1452 base sta tion 1x 50114525 Power supply unit 1x 50114519 KB PS2 1 IT 1902 Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the base stati...

Страница 9: ...he data can therefore be further processed in all standard programs Required parts 1x IT 1452g 1D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x...

Страница 10: ...D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x 3m straight or 1x 50114523 KB USB 2 IT190x 5m spiral Procedure 1 Install the USB serial driver c...

Отзывы: