Leuze it 1452g Скачать руководство пользователя страница 1

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

[email protected]  •  www.leuze.com

We

 re

serve 

th

right

 t

o

 ma

ke

 c

h

an

ges 

• 

DS_IT14

52g_en

_

5

0130

034.

fm

Hand-held scanner for bar codes

Transmission to base station via Bluetooth 
standard V2.1

Large reading field for detecting high-con-
trast codes

Robust trigger button

Built-in decoder

Indicator upon successful read

RS 232, USB and PS/2 interface

Operating temperature 0°C to 50°C

5 V

DC

Accessories

TTL-RS 232 cable

Part no. 50114517

PS/2 cable

 

Part no. 50114519 

USB cable, 3m 

Part no. 50114521

USB helix cable, 5m 

Part no. 50114523

Power supply unit

 

Part no. 50114525 

UL

US

C

LISTED

IP

IP 42

42

Dimensioned drawing

62

62

82

82

17317

3

Hand-held scanner 

IT 1452g 1D-2

 

with Bluetooth

Bluetooth base station 

Base for IT 1452

Electrical connection

for RS 232 cable

for USB cable 

for PS/2 cable 

9-pin Sub-D

Signal

Base for IT 1452 RJ41

2

TXD

4

3

RXD

5

5

GND

3

7

CTS

6

8

RTS

8

9

5VDC

7

USB type A

Signal

Base for IT 1452 RJ41

1

5VDC

7

2

Data  -

10

3

Data  +

9

4

GND

3

Mini DIN connector

Mini DIN socket

Signal

Base for IT 1452 RJ41

1

-

PC  Data

4

2

2

NC

3

3

GND

3

4

4

5VDC

7

5

-

PC  Clock

5

6

6

NC

-

1

KB  data

8

-

5

KB  clock

6

IT 1452g

Hand-held bar code scanner with Bluetooth data transmission

   IT 1452g - 01

Specifications and description

en

01

-2

01

5/

09

5

0

1

300

34

Содержание it 1452g

Страница 1: ...0114521 USB helix cable 5m Part no 50114523 Power supply unit Part no 50114525 UL US C LISTED IP IP 42 42 Dimensioned drawing 62 62 82 82 173 173 Hand held scanner IT 1452g 1D 2 with Bluetooth Bluetoo...

Страница 2: ...ons 173x82x62mm 101x131x81mm Shock resistance 30 falls from a height of 1 5m 50 falls from a height of 1m Environmental data Ambient temp operation 0 C 50 C 0 C 50 C Ambient temp storage 40 C 70 C 40...

Страница 3: ...pulling the trigger A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an acoustic signal to confirm that the label has been read if n...

Страница 4: ...COM port emulation only The command is to be sent at the set baud rate parity and data and stop bits The command for activation is SYN T CR ASCII decimal values 022 084 013 To cancel read readiness se...

Страница 5: ...n the computer 3 and to the base station 2 3 Plug one end of the power supply unit cable into the base station 4 and the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacen...

Страница 6: ...T Procedure 1 Insert the KB JST HS 300 cable into the MA 2xxi 2 Connect the interface cable to cable KB JST HS 300 Connect the interface cable and the power supply unit to the base station see Con nec...

Страница 7: ...ield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the...

Страница 8: ...D 2 1x 50130499 Base for IT 1452 base sta tion 1x 50114525 Power supply unit 1x 50114519 KB PS2 1 IT 1902 Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the base stati...

Страница 9: ...he data can therefore be further processed in all standard programs Required parts 1x IT 1452g 1D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x...

Страница 10: ...D 2 1x 50130499 Base for IT 1452 base station 1x 50114525 Power supply unit 1x 50114521 KB USB 1 IT190x 3m straight or 1x 50114523 KB USB 2 IT190x 5m spiral Procedure 1 Install the USB serial driver c...

Отзывы: