easyTune – Manual fine tuning of the switching threshold
With homogeneous label material, the signal in the gap between two labels is
much larger compared to the signal on the label.
For the taught switching threshold, there is a high function reserve in both the gap
as well as on the label, and the sensor functions reliably.
To achieve a better function reserve, it can be advantageous to change the taught
switching threshold, especially for inhomogeneous label material.
The sensitivity of the sensor and, thus, the switching threshold can be adjusted
with the
easyTune function, which is in principle comparable to a potentiometer.
NOTICE
Use of the
easyTune function temporarily deactivates the ALC func-
tion!
The
ALC function is reactivated after teaching again.
9
The sensitivity of the sensor can be adjusted by pressing the teach button (+) or
the label button (-).
Increase sensitivity:
Ä
Briefly press the teach button (+).
ð
A single flash of the green ON LED confirms button actuation.
Reduce sensitivity:
Ä
Briefly press the label button (-).
ð
A single flash of the yellow OUT LED confirms button actuation.
15
EN