Manual mode
With manual
easy Teach, the operator selects the detection process (ultrasonic or
optical) in advance ("Configuration of the easy Teach mode").
NOTICE
Ä
To switch the
easy Teach mode from intelligent to manual, press
the label button for longer than 12 seconds.
8
With manual
easy Teach, the operator can deliberately teach a label with a spe-
cific detection process. As a result, specific label types can be taught for each de-
tection process.
– Unlike intelligent
easy Teach, with manual easy Teach you can switch the
detection process after ending the teach event and then teach another label
type with the second detection process without overwriting the teach values
of the first detection process.
– For example, you can teach a transparent label 1 with the
ultrasonic detec-
tion process and simultaneously teach a paper label 2 with the
optical detec-
tion process.
– If the roll is changed from label 1 to label 2, simply change the detection
process ("Select active detection process") – a new teach does not need to
be performed.