background image

(I)GS 63B… - 02

2020/08/19

Sensor adjustment (teach-in) via teach input for (I)GS 63B

The following description applies to PNP switching logic!

The device setting is stored in a fail-safe way. A reconfiguration following power failure or switch-off is thus not required.

Line teach while label tape is passing through

Preparation: Insert the label tape in the correct position in the sensor (align the middle of the tape to the sensor marking).

The red LED illuminates and the warning output is activated if a teaching error occurs (e.g. the label cannot be reliably detected due to 

insufficient signals). 
Regardless of the state, the green LED is on when the teach event is terminated, the yellow LED indicates the current switching state.

Line teach if the label tape cannot be advanced (static teach)

Preparation: Remove one or more labels from the base material and place this blank area in the sensor. The label tape must now not be 

advanced further.
The process is identical to the line teach with moving label tape.

Adjusting the switching behavior of the switching output – light/dark switching

UTeach

Not connected

Internal pull-down resistor pulls the 

input down to zero

Teach button can be operated; 

all functions adjustable

UTeach low

2V

Low level

Teach button can be operated; 

all functions adjustable

UTeach high

8V

High level

Teach button disabled; 

button has no function

UTeach

> 2V … < 8V

Not permitted

Pulse only 

necessary if 

a low-level 

was applied 

previously

Activation of the teach-in:

Action starts with the falling 

edge:
t

Teach

 = 1100 … 1900ms

The rising edge starts the teach event. The green 

and yellow LEDs flash alternately 3x per second as 

long as the signal is high.
Advance the label tape so that several label gaps 

pass the sensor, thereby allowing the teach values 

to be determined. 

The teach event is concluded with the 

falling edge.
50ms after the falling edge, the sensor 

returns to normal operation. 
The teach button is enabled again after 

max. 3 s

Pulse only 

necessary if 

a low-level 

was applied 

previously

Activation of the teach 

switching output:

Action starts with the falling 

edge:
t

Teach

 = 2100 … 3000ms

Switching output switches in the label gap 

(20 … 900ms)
Switching output switches on the label 

(1100 … 2000ms)

The teach event is concluded with the 

falling edge.
50ms after the falling edge, the sensor 

returns to normal operation. 
The teach button is enabled again after 

max. 3 s

t

20 ms … 

1100 … 1900ms

50 ms … 

50 ms

Button disabled

Button enabled

Button disabled

Button enabled after 3s

t

2100 … 3000ms

20 … 900ms

1100 … 2000ms

20 ms … 

Button disabled

Button enabled

Button disabled

Button enabled after 3s

(I)GS 63B

Содержание GS63B/6.3-S8

Страница 1: ...3B 3 Storage of up to 30 teach values in the sensor Warning output for indicating teach or function errors IGS63B Easy adjustment via lockable teach button or teach input 3mm Accessories available sep...

Страница 2: ...dy Yellow LED Switching signal in the label gap Red LED Teaching error function error Mechanical data Housing base Diecast zinc chemically nickel plated surface silver Upper part of housing PC plastic...

Страница 3: ...6 3 S8V 50128005 GS63B 6D 3 S8V 50128009 GS63B 66 3 S8 50143910 2 antivalent switching outputs GS63B 6 3 200 S8 50129248 With warning output IGS63B 6 3 50128013 IGS63B 6 3 200 S12 50128014 IGS63B 6D 3...

Страница 4: ...hanges between gap and label Short instructions for sensor adjustment via teach button for I GS 63B teach in Top view of sensor with operating button plugged 2 s 7 s 12 s Standard function Normal oper...

Страница 5: ...teach in Advance the label tape at a maximum speed of 20m min through the sensor so that at least 3 7 labels pass through the sensor Static teach in Blank area remains at the same position in the sen...

Страница 6: ...ions adjustable UTeach low 2V Low level Teach button can be operated all functions adjustable UTeach high 8V High level Teach button disabled button has no function UTeach 2V 8V Not permitted Pulse on...

Страница 7: ...e Use the following chart for this purpose Pulse only necessary if a low level was applied previously Activation store current teach value Action starts with the falling edge tTeach 580 620ms Select s...

Страница 8: ...vironmental durability The used materials feature very good resistance to weak acids and bases as well as to UV exposure Contact with organic solvents is possible only to a limited extent and only for...