Electrical connection
Leuze electronic GmbH + Co. KG
BPS 307i
49
7.5.3
SSI connection cable
Tab. 7.3:
SSI connection cable KB 307
KB 307-3000
KB 307-10000 FLEX
Designation
Assignment
WH
GY
FE
Functional earth
WH-BK
WH
GNDIN
Negative supply voltage
(0 VDC)
BK
BN
VIN
+18 … +30 VDC supply
voltage
GY
VT
SWIO1
Sw. input/output 1 (con-
figurable)
WH-GN
BK
SWIO2
Sw. input/output 2 (con-
figurable)
WH-YE
BU
CLK-
- Clock line SSI
(Input electrically iso-
lated)
WH-RD
GN
DATA-
- Data line SSI
(Output electrically iso-
lated)
YE
RD
CLK+
+ Clock line SSI
(Input electrically iso-
lated)
RD
YE
DATA+
+ Data line SSI
(Output electrically iso-
lated)
---
PK
Not connected
VT
---
Reserved
---
WH-BN
---
Reserved
---
BN
---
Reserved
---
WH-OG
---
Reserved
---
OG
---
Reserved
---
GN
---
Reserved
---
BU
---
Reserved
---
7.5.4
Service USB
NOTICE
PC connection!
Ä
The service USB interface of the BPS can be connected to the USB interface on the PC with
a standard USB cable (plug combination - Mini-B type / Type A).
Ä
If possible, use the specific USB service cable from Leuze (see chapter 14.3 "Cables acces-
sories").
5-pin, Mini-B plug for connecting to the service USB.