Online commands
Leuze electronic GmbH + Co. KG
BCL 208i
46
Reference code teach-in
Command
’RT’
Description
This command enables a reference code to be defined quickly by reading an exam-
ple label.
Parameter
’RTy’
y
Function
’1’
Defines reference code 1
’2’
Defines reference code 2
’+’
Activates the definition of reference code 1 up to the value of Param-
eter no_of_labels
’-’
Ends the teach event
Acknowledgment
The bar code reader responds with command
’RS’
and corresponding status (see
command ’RS’). After a bar code has been read, it sends the result in the following
format:
’
RCyvxxzzzzz
’
y
,
v
,
x
and
z
are placeholders (variables) for the actual input.
y
Defined reference code no.
’1’
(Code 1)
’2’
(Code 2)
v
Storage location for reference code
’0’
RAM+EEPROM
’3’
RAM only
xx
Defined code type (see command 'CA')
z
Defined code information (1 … 63 characters)
NOTICE
With this function, only code types are recognized that are identified using the
autoConfig
func-
tion or which were set in the set-up.
Ä
After each reading via an ’RTy’ command, explicitly switch off the function again since failure
to do so will interfere with other commands as well as prevent execution of a new ’RTx’ com-
mand.