Recommended settings

Observation

Measure

Action

After teaching, the yellow
LED and the switching
output flicker if the label is
moved through the sen-
sor:
The function reserve on
the label is too low.

Reduce sensitivity of the
sensor
(upward shift of the
switching threshold)

Repeatedly press the mi-
nus button (-) briefly until
the sensor detects the
moving label stably and
without interruption.

In rare cases, a highly in-
homogeneous carrier
tape can affect the func-
tional reliability. The yel-
low LED and the switch-
ing output flicker if the
blank carrier tape is
moved through the sensor
without labels:
The function reserve on
the carrier is too low.

Increase sensitivity of the
sensor
(downward shift of the
switching threshold)

Repeatedly press the
teach button (+) briefly
until the sensor detects
the moving carrier tape
without labels stably and
without flickering.

Manual locking/unlocking of the buttons on the device

To protect against erroneous operation, the locking of the buttons is intended to
prevent a button on the device from accidentally being pressed. Accidental button
actuation could unintentionally trigger the 

easyTune function or the teaching of the

device and thereby deactivate the 

ALC function.

9

Ä

Press the teach button (+) and the minus button (-) simultaneously until the
green ON LED flashes at approx. six times per second.

Ä

Release the teach button (+) and the minus button (-).

ð

The buttons are now locked and can no longer be operated.

ð

The buttons are unlocked using the same button combination.

NOTICE

Manual locking of the buttons on the device is stored in volatile mem-
ory.

13

EN

Содержание 50142870

Страница 1: ...IGSU 14E Ultrasonic label fork Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 05 07 50143646 www leuze com...

Страница 2: ...1Figure part 1 A B 2...

Страница 3: ...2 12 s 2 7 s C B A D 7 s E F 7 12 s 2 7 s 3 3...

Страница 4: ...4 2 7 s 5 7 12 s 4...

Страница 5: ...6 12 s 7 2 7 s 5...

Страница 6: ...8 2 s 2 s 9 7 s 10 A B T t HIGH LOW 20 ms 20 ms 6...

Страница 7: ...11 7...

Страница 8: ...el gap Dark switching signal on the label 1 A Label center position B Label run To achieve a high switching accuracy place the label tape on the lower fork with slight tension Align the label tape wit...

Страница 9: ...LED green Constantly ON when operating voltage is applied OUT LED yellow Indicates the switching signal LED is ON if the sensor detects label gaps The display is independent of the output setting WARN...

Страница 10: ...tape can be stopped immediately The number of labels to be transported is always based on the material com bination From experience approximately 2 10 labels should be advanced through the sensor If...

Страница 11: ...g calculated for maxi mum function reserve All values are saved and are non volatile retaining their validity as long as the dy namic parameters of the system remain unchanged and the material is not...

Страница 12: ...abel and the sensor functions reliably To achieve a better function reserve it can be advantageous to change the taught switching threshold especially for inhomogeneous label material The sensitivity...

Страница 13: ...shift of the switching threshold Repeatedly press the teach button briefly until the sensor detects the moving carrier tape without labels stably and without flickering Manual locking unlocking of the...

Страница 14: ...least 20 ms 10 A Buttons locked B Buttons can be operated T Duration of the teach signal Duration T ms Function 20 80 easy Teach while the label tape is passing through 120 180 Static teach 220 280 C...

Страница 15: ...s also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can the...

Отзывы: