Activate or deactivate 

ALC function

The 

ALC function can be manually deactivated and activated.

7

Ä

Press the minus button (-) until the green ON LED and the yellow OUT LED
flash synchronously.

Ä

Release the minus button (-).

NOTICE

The manual deactivation/activation of the 

ALC function is stored in

non-volatile memory in the sensor.

easyTune – Manual fine tuning of the switching threshold

With homogeneous label material, the signal in the gap between two labels is
much larger compared to the signal on the label. 
For the taught switching threshold, there is a high function reserve in both the gap
as well as on the label, and the sensor functions reliably.
To achieve a better function reserve, it can be advantageous to change the taught
switching threshold, especially for inhomogeneous label material.
The sensitivity of the sensor and, thus, the switching threshold can be adjusted
with the 

easyTune function, which is in principle comparable to a potentiometer.

NOTICE

Use of the 

easyTune function temporarily deactivates the ALC func-

tion!

The 

ALC function is reactivated after teaching again.

8

The sensitivity of the sensor can be adjusted by pressing the teach button (+) or
the minus button (-).

Increase sensitivity:

Ä

Briefly press the teach button (+).

ð

A single flash of the green ON LED confirms button actuation.

Reduce sensitivity:

Ä

Briefly press the minus button (-).

ð

A single flash of the yellow OUT LED confirms button actuation.

12

EN

Содержание 50142870

Страница 1: ...IGSU 14E Ultrasonic label fork Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 05 07 50143646 www leuze com...

Страница 2: ...1Figure part 1 A B 2...

Страница 3: ...2 12 s 2 7 s C B A D 7 s E F 7 12 s 2 7 s 3 3...

Страница 4: ...4 2 7 s 5 7 12 s 4...

Страница 5: ...6 12 s 7 2 7 s 5...

Страница 6: ...8 2 s 2 s 9 7 s 10 A B T t HIGH LOW 20 ms 20 ms 6...

Страница 7: ...11 7...

Страница 8: ...el gap Dark switching signal on the label 1 A Label center position B Label run To achieve a high switching accuracy place the label tape on the lower fork with slight tension Align the label tape wit...

Страница 9: ...LED green Constantly ON when operating voltage is applied OUT LED yellow Indicates the switching signal LED is ON if the sensor detects label gaps The display is independent of the output setting WARN...

Страница 10: ...tape can be stopped immediately The number of labels to be transported is always based on the material com bination From experience approximately 2 10 labels should be advanced through the sensor If...

Страница 11: ...g calculated for maxi mum function reserve All values are saved and are non volatile retaining their validity as long as the dy namic parameters of the system remain unchanged and the material is not...

Страница 12: ...abel and the sensor functions reliably To achieve a better function reserve it can be advantageous to change the taught switching threshold especially for inhomogeneous label material The sensitivity...

Страница 13: ...shift of the switching threshold Repeatedly press the teach button briefly until the sensor detects the moving carrier tape without labels stably and without flickering Manual locking unlocking of the...

Страница 14: ...least 20 ms 10 A Buttons locked B Buttons can be operated T Duration of the teach signal Duration T ms Function 20 80 easy Teach while the label tape is passing through 120 180 Static teach 220 280 C...

Страница 15: ...s also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can the...

Отзывы: