background image

easy Teach while the label tape is passing through (dynamic)

During the 

easy Teach process, a two-point calibration is performed on the carrier

and the label.

NOTICE

With respect to detection reliability, the 

easy Teach process is gener-

ally to be preferred over the static teach process.

Preparation: Insert label tape into the sensor.

4

Ä

Press the teach button until the green ON LED and the yellow OUT LED flash
synchronously.

Ä

Release the teach button.

Ä

Allow the label tape to advance through the sensor at a maximum speed of
50 m/min.

ð

The sensor indicates the belt transport by a more rapid synchronous
flashing of the green ON LED and yellow OUT LED.

– If sufficient teach values are determined, the sensor automatically terminates

the teach event and goes into standard mode. 
The transport of the label tape can be stopped immediately.

– The number of labels to be transported is always based on the material com-

bination. From experience, approximately 2-10 labels should be advanced
through the sensor.

– If the teach event is faulty (e.g., unfavorable material combination, uneven

transport, jittering during transport), the red WARN LED illuminates and the
warning output (if present for the sensor model) is activated. 
If the fault cannot be rectified, e.g., via the 

easyTune function, the label ma-

terial cannot be detected with the device.

Static teach on the label carrier without transport

With the static teach process, a one-point calibration is performed on the blank
carrier. This process is especially advantageous because no labels are lost while
teaching.
Preparation: depending on the label size, pull off one or more labels from the car-
rier and insert the blank area into the sensor.

5

Ä

Press the teach button until the green ON LED and the yellow OUT LED flash
alternately.

Ä

Release the teach button.

10

EN

Содержание 50142870

Страница 1: ...IGSU 14E Ultrasonic label fork Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 05 07 50143646 www leuze com...

Страница 2: ...1Figure part 1 A B 2...

Страница 3: ...2 12 s 2 7 s C B A D 7 s E F 7 12 s 2 7 s 3 3...

Страница 4: ...4 2 7 s 5 7 12 s 4...

Страница 5: ...6 12 s 7 2 7 s 5...

Страница 6: ...8 2 s 2 s 9 7 s 10 A B T t HIGH LOW 20 ms 20 ms 6...

Страница 7: ...11 7...

Страница 8: ...el gap Dark switching signal on the label 1 A Label center position B Label run To achieve a high switching accuracy place the label tape on the lower fork with slight tension Align the label tape wit...

Страница 9: ...LED green Constantly ON when operating voltage is applied OUT LED yellow Indicates the switching signal LED is ON if the sensor detects label gaps The display is independent of the output setting WARN...

Страница 10: ...tape can be stopped immediately The number of labels to be transported is always based on the material com bination From experience approximately 2 10 labels should be advanced through the sensor If...

Страница 11: ...g calculated for maxi mum function reserve All values are saved and are non volatile retaining their validity as long as the dy namic parameters of the system remain unchanged and the material is not...

Страница 12: ...abel and the sensor functions reliably To achieve a better function reserve it can be advantageous to change the taught switching threshold especially for inhomogeneous label material The sensitivity...

Страница 13: ...shift of the switching threshold Repeatedly press the teach button briefly until the sensor detects the moving carrier tape without labels stably and without flickering Manual locking unlocking of the...

Страница 14: ...least 20 ms 10 A Buttons locked B Buttons can be operated T Duration of the teach signal Duration T ms Function 20 80 easy Teach while the label tape is passing through 120 180 Static teach 220 280 C...

Страница 15: ...s also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can the...

Отзывы: