Technical data
14
AMS 348
i
SSI
Leuze electronic GmbH + Co. KG
4
Technical data
4.1
Technical data of laser measurement system
4.1.1
General specifications AMS 348
i
SSI
Measurement data
AMS 348
i
40 (H)
SSI
AMS 348
i
120 (H)
SSI
AMS 348
i
200 (H)
SSI
AMS 348
i
300 (H)
SSI
Measurement range
0.2 … 40m
0.2 … 120m
0.2 … 200m
0.2 … 300m
Accuracy
± 2mm
± 2mm
± 3mm
± 5mm
Reproducibility
1)
0.3mm
0.5mm
0.7mm
1.0mm
Light spot diameter
≤
40mm
≤
100mm
≤
150mm
≤
225mm
Output time
1.7 ms
Response time
14ms
Basis for contouring error calcu
-
lation
7ms
Resolution
Adjustable; see chapters on individual interfaces
Temperature drift
≤
0.1mm/K
Ambient temperature sensitivity
1ppm/K
Air pressure sensitivity
0.3ppm/hPa
Traverse rate
≤
10m/s
Electrical data
Supply voltage Vin
2)
18 … 30VDC
Current consumption
Without device heating:
≤
250mA / 24VDC
With device heating:
≤
500mA / 24VDC
Optical data
Transmitter
Laser diode, red light
Laser class
2 in acc. with IEC 60825-1:2014
Wavelength
655nm
Impulse duration
≤
18µs
Max. output power (peak)
≤
4mW
PROFINET interface
Interface type
PROFINET-RT with integrated switch
for BUS IN and BUS OUT
Protocol
PROFINET RT communication
Conformance class
B
SSI interface
Interface type
SSI interface
SSI clock rate
50kHz … 800kHz
Data format
Controls and indicators
Keyboard
4 keys