Terms used in this manual
Table 1.2:
Terms
AOPD
Active Opto-electronic Protective Device
AOPD response time
Time between penetration into the active protective field of the AOPD and
the actual switching off of the OSSDs.
AutoReset
When an error indication occurs, caused, for example, by faulty external
wiring, the AOPD attempts to start again. If the error is no longer present,
the AOPD returns to normal operation mode.
Contactor Monitoring (EDM) Also called "External Device Monitoring", monitors the positive-guided
normally closed contacts of downstream relays, contactors or valves
DoubleScan
Two scans are made: Beams must be interrupted in two consecutive
scans, before the Receiver switches OFF.
FS
Factory setting
S/RS interlock
Start/restart interlock
Scan
All beams, beginning with the synchronization beam, are activated and
deactivated one after the other, i.e. only one beam is active at a time.
SSD1,.. ,SSD4, Dyn SSD
Safety-relevant switching outputs (transistors)
Start/restart interlock
Prevents automatic start after the supply voltage has been turned on, or
after the protective field has been penetrated