Display elements
16
SOLID-2SF-M
Leuze electronic
Review status, , Mittwoch, 8. April 2015
DEUTSCH
E
NGLISH
FRAN
ÇAIS
ITALIA
N
O
ESPAÑOL
N
EDERLANDS
4.2.1
7-Segment display
After the supply voltage is switched on, the following data appears on the 7-Segment
display of the Receiver:
Table 4.2:
Receiver, 7-Segment permanent displays
Table 4.3:
Receiver, 7-Segment temporary event display
4.2.2
LED displays
Receiver, LED status displays
Table 4.4:
Receiver LED displays
7-Segment display
Meaning
Permanent display after startup
1 or 2
Transmission channel TC1 or TC2 display
7-Segment display
Meaning
Temporary event displays, 1 s per display
E xx
Display of locking status “Malfunction”, which can be released by the user;
E xx = Error code (see Chapter 9). The display shows E, 3 (1st position)
and 0 (2nd position) alternating, and then repeats this sequence.
F xx.
Locking status display "device fault" and an internal fault code. Receiver
must be replaced.
1 or 2 flashing
Flashing transmission channel number -> weak signal display, device not
adjusted optimally or dirty
LED
Color Meaning
LED1
Red/
green
Red
= At least one safety output SSD in OFF state
Green
= All safety outputs SSDs in the ON state
No display
= Device without supply voltage