9.3
Electrical data
Power supply
Voltage supply
1)
1)
Protective Extra Low Voltage (PELV) - protective extra-low voltage with reliable disconnec-
tion.
For UL applications: only for use in class 2 circuits according to NEC.
+24VDC +20% / -30%
Overcurrent protection
via fuse 2.5A (4A with heating) semi time-lag in the
switch cabinet
Current consumption
approx. 1A (approx. 2.5A with heating)
Power consumption
24 … 75W at 24VDC
Overvoltage protection
overvoltage protection with protected limit stop
Voltage dips
acc. to EN 61496-1 (VDE 0113, part 201)
Inputs (at Y1)
Restart/Reset
command device for operating mode with restart-dis-
able and/or device reset; dynamically monitored,
24VDC optically decoupled (activate for 0.12 … 3s)
Detection field changeover
selection between max. 4 detection field pairs via four
control lines with internal monitoring, 24VDC opto-
decoupled
Interfaces
1)
1)
With
RODplussoft
, all three interfaces can be used for configuration. Measurement data
can be transferred either via Y2 or Y4.
RODsoft
can only communicate with the ROD4…plus via interface Y3.
Y2
Ethernet
10/100 MBd, TCP/IP peer-to-peer
Y3
Service RS 232
57.6kBd, 8 data bits, no parity, 1 stop bit, setting per-
manently stored
Y4
RS 232/422
RS 232/422 reversible, factory setting 115kBd, 8 data
bits, no parity, 1 stop bit