EN
22
Switching outputs HIGH/LOW
(U
B
-2V) / 2V (
100mA, push-pull)
Switching inputs HIGH/LOW
18 … 30VDC / 0 … 2VDC
PROFIBUS interface (
LxS 36…/PB
only) RS 485, PROFIBUS DP/DPV1 slave,
9.6kBaud … 6MBaud
Encoder interface (
LPS 36…/EN
only)
24V single ended (A+, B+) or
5V differential (A+/A-, B+/B-),
max. current consumption 140mA,
max. pulse frequency 300kHz
Analog output (
LES 36…/VC6
only)
voltage 1 … 10V, R
L
2k
and
current 4 … 20mA, R
L
500
Housing
aluminum frame with plastic cover
Optics cover
glass,
LRS 36/6.10
: plastic
Weight
approx. 620g
Connection type
M12 connectors
Dimensions
see
Ambient temp. (operation/storage)
-30°C … +50°C / -30°C … +70°C
Rel. air humidity
max. 90% (non-condensing)
VDE safety class
III
Degree of protection
IP 67
5)
Standards applied
IEC/EN 60947-5-2
Conformity
CE, CDRH
Certifications
UL 508, C22.2 No.14-13
1)
6)
1) For UL applications: only for use in class 2 circuits according to NEC.
2) Luminosity coefficient 6% ... 90%, entire detection range, at 20°C after 30minutes
warmup time, medium range U
B
.
3) Minimum and maximum values depend on measurement distance.
4) Reflectivity 90%, identical object, identical environment conditions, measurement
object
50x50mm².
5) Only with screwed-on M12 connectors or mounted caps.
6) These sensors shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7).