Electrical connection
Leuze electronic
Technical description LES
45
TNT
35/7-2
4
V
Connect the ground potential to the light section sensors
Figure 6.3:
Connecting the ground potential to the light section sensor
Connecting the cable shield in the switch cabinet
Figure 6.4:
Connecting the cable shield in the switch cabinet
Devices produced after April 2011 are
equipped with an additional ground-
ing terminal.
All devices can also be connected
to ground potential at the M4
threaded hole on the dovetail.
Attention!
Place lock washer
underneath and
check the penetration
of the anodized
coating!
• Shield connected flat to PE
• Connect PE star point with short cables
• Galvanized mounting sheet steel
Comment
:
Depicted shield components from Wago,
series 790 ...:
- 790-108 Shield clamping bracket 11 mm
- 790-300 Busbar holder for TS35