Response time for OS1 and OS2 safe outputs on input deactivation:
• Typical 7 ms
• Maximum 15 ms
Response time on door release:
• Typical 7 ms
• Maximum 12 ms
EDM input signal state change maximum delay: 500 ms
6.3.3 Electrical data for O3/O4 signalling outputs
Rated operation voltage U
e
:
24 Vdc
Type of output:
PNP
Maximum current for Ie output:
0.1 A
Category of use:
DC12; Ue=24 Vdc, Ie=0.1 A
Short-circuit detection:
No
Protection against overcurrent:
Yes
Internal self-resetting protection fuse:
1.1 A
6.3.4 RFID sensor data
Assured intervention distance S
ao
:
2 mm
Assured releasing distance S
ar
:
4 mm (actuator not locked)
10 mm (actuator locked)
Rated intervention distance S
n
:
2.5 mm
Repeatability precision:
≤
10% S
n
Differential travel:
≤
20% S
n
Maximum switching frequency:
1Hz
Minimum distance between 2 identical devices to avoid reciprocal radio interferences:
2 mm
6.4 Conformity with the following standards:
EN ISO 14119, EN 60947-5-3, EN 60947-1, EN 60204-1, EN ISO 12100, EN 0529,
EN 61000-6-2, EN 61000-6-3, BG-GS-ET-19, IEC 61508, SN 29500, EN ISO 13849-1,
EN ISO 13849-2, EN 62061, EN 61326-1, EN 61326-3-1, EN 61326-3-2,
ETSI 301 489-1, ETSI 301 489-3, ETSI 300 330-2, UL 508, CSA 22.2 No.14
6.5 Conforming to the requirements prescribed by:
2006/42/EC Machine Directive
2004/108/EC Electromagnetic compatibility
R&TTE 1999/05/EC Directive
FCC Part 15 Statements:
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired
operation.
7 DISPOSAL
At the end of service life product must be disposed of properly, according to the rules
in force in the country in which the disposal takes place.
8 SUPPORT
Telephone number for 24-hour standby service: +49 (0) 7021 573-0
Service hotline: +49 (0) 8141 5350-111
Monday to Thursday, 8.00 a.m. to 5.00 p.m. (UTC+1)
Friday, 8.00 a.m. to 4.00 p.m. (UTC +1)
E-mail: [email protected]
Return address for repairs:
Service Center Leuze electronic GmbH + Co. KG
In der Braike 1
D-73277 Owen / Germany
9 EC CONFORMITY DECLARATION
Leuze electronic GmbH + Co. KG
In der Braike 1, D-73277 Owen/Germany
We hereby declare that the L300 safety locking device (see name plate for part no.)
in the form in which it is marketed by us conforms with the relevant safety and health
requirements of the listed EC directives (see section 6.4, including all changes) and
that the listed standards (see section 6.5, including all changes) were used in its design
and construction.
Owen, 2015/12
Ulrich Balbach, Managing Director
10 DIMENSIONAL DRAWINGS
L300-MxxC3-xxxxx
46
5.6
144
61.9
211.5
40.4
30
2.4
5.4
40
24.1
18.3
46
40
38.8
L300-MxxC3-xxxxx-KYPB
68
5.6
144
83.9
233.5
40.4
30
2.4
5.4
40
5
24.1
18.3
46
40
38.8
38.1
22.8
Ø
38
30
39.3
Ø
21.4
L300-MxxC3-xxxxx-PB
68
40.4
30
2.4
5.4
40
24.1
18.3
46
40
38.8
39.3
5.6
144
83.9
233.5
5
Ø
38
30
Ø
21.4
AC-L300-xCA
16
Ø15
32.1
29
21
5.5
21.6
5.5
40
R >80
59.4
21
38.4
48.1
5.2
5.4