IT 1911i / IT 1981i - 03
2015/09
Connecting the IT 1911i / IT 1981i to the MA 2xxi
Required parts:
1x
IT 1911i ER-3 or IT 1981i FR-3
1x
50122431
Base for IT 1911i
1x
50114517 KB 232-1 IT 190x
1x
50123862
Power supply unit for Base for IT 1911i
1x
50113397
KB JST-HS-300
1x
MA 2xxi
for the respective fieldbus system
Procedure:
1.
Connect cable KB JST-HS-300 to the system connector on the MA 2xxi.
2.
Connect the interface cable to cable KB JST-HS-300. Connect the interface cable and the
power supply unit to the base station (see "Connecting the IT 1911i / IT 1981i to the serial
PC interface").
3.
Scan the adjacent 2D code.
The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, postfixes
<CR><LF>.
4.
Return the hand-held scanner to the base station to apply the settings. This procedure is
concluded with audible confirmation signals.
Notice!
To charge the hand-held scanner, the power supply unit must be plugged in
and the hand-held scanner placed in the base station.
IT 1911i / IT 1981i