Adjusting the switching points (teach) via the teach input

The switching points of the sensor outputs OUT1/OUT2 are set to 3000mm or 6000mm on delivery. 
By means of a simple teach event, the two switching points can be individually taught to an arbitrary distance within the operating 

range. The Leuze PA1/XTSX-M12 Teach Adapter can be used for this purpose. The adapter can also be used to easily switch the 

output function from NO contact to NC contact.

Note!
Please note that the switching point is taught when GND is connected and the output function is reversed when UB is 

connected. If no sensor action is desired, pin 2 must remain unconnected!
The 2-point window-teach can be configured either with the control buttons or via the IO-Link interface. Adjustment via 

the teach input is not possible.

Adjusting the switching function (NC/NO) via the teach input

The switching function of both sensor outputs is set to normally open (NO) on delivery. 
If the switching function is changed, the switching output is changed to the opposite state (toggled).

1-point teach of output OUT1

1-point teach of output OUT2

1.Place object at desired switching distance.

1.Place object at desired switching distance.

2.For the adjustment of OUT1, connect input Teach-IN to GND 

for 2 … 7s (Leuze teach adapter: position "Teach-GND"). 

The current state of output OUT1 is frozen during the teach 

event.

2.For the adjustment of output OUT2, connect input Teach-IN to 

GND for 7 … 12s (Leuze teach adapter: position "Teach-

GND"). 

The current state of output OUT2 is frozen during the teach 

event.

3.The yellow LED flashes at 3Hz and is then ON. 

The current object distance has been taught as the new 

switching point. 

3.The yellow LED flashes at 3Hz. 

The current object distance has been taught as the new 

switching point. 

4.Error-free teach: switching behavior according to the diagram 

shown above. 

Faulty teach (object may be too close or too far away – please 

note operating range): 

yellow LED flashes at 5Hz until an error-free teach event is 

performed. 

Output OUT1 is inactive as long as there is a teach error.

4.Error-free teach: switching behavior according to the diagram 

shown above. 

Faulty teach (object may be too close or too far away – please 

note operating range): 

yellow LED flashes at 5Hz until an error-free teach event is 

performed. 

Output OUT2 is inactive as long as there is a teach error.

Changeover of the switching function of output 

OUT1

Changeover of the switching function of output 

OUT2

1.To change the switching function, connect input Teach-IN to 

UB for 2 … 7s (Leuze teach adapter: position "Teach-U

B

"). 

The current state of output OUT1 is frozen while the adjust

-

ment is made.

1.To change the switching function, connect input Teach-IN to 

UB for 7 … 12s (Leuze teach adapter: position "Teach-U

B

"). 

The current state of output OUT2 is frozen while the adjust

-

ment is made.

2.The green and yellow LEDs flash alternately at 2Hz. 

The switching function was changed over. 

The switching behavior corresponds to the diagram shown 

above.

2.The green and yellow LEDs flash alternately at 5Hz. 

The switching function was changed over. 

The switching behavior corresponds to the diagram shown 

above.

HTU430B

Содержание HTU430B Series

Страница 1: ...design NEW Process data and configuration via IO Link interface NEW Five operating modes scanning synchronous multiplex activation and throughbeam operation 300 3000mm 600 6000mm 15 30 V DC Accessori...

Страница 2: ...Ultrasonic transducer Piezoceramic 4 4 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Installation position Any Environment...

Страница 3: ...X Advanced design 3 Teach button on the sensor Pin assignment of connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset L IO Link communication or push pul...

Страница 4: ...First taught object distance Second taught object distance Output switching behavior NO normally open NC normally closed Far Close Close Far Dead zone Sensor OUT active Yellow LED ON Green LED OFF OU...

Страница 5: ...adjust output OUT2 press button 2 for 7 12s until the yellow and green LED flash alternately at 3Hz 3 Release the teach button to complete the teach event The current object distance has been taught...

Страница 6: ...adapter position Teach GND The current state of output OUT2 is frozen during the teach event 3 The yellow LED flashes at 3Hz and is then ON The current object distance has been taught as the new swit...

Страница 7: ...ughbeam sensor requires 2 sensors which are electrically connected through one line Switching outputs OUT1 OUT2 Switching point 1 2 The switching points can be directly entered as distance value in mm...

Страница 8: ...HTU430B X3 LT4 M12 03 2019 05 8 HTU430B...

Отзывы: