Device functions and indicators
The sensor has two buttons for adjusting output OUT1 and output OUT2. Alternatively, all adjustments can also be made via IO-
Link. The multi funct teach input can be used to perform the 1-point teach and the changeover of the switching function (NO con
-
tact/NC contact).
Switching behavior
Note!
The switching behavior is not defined in the dead zone.
Switching behavior with 2-point window-teach as a function of the switching function
Note!
In measurement operation, the yellow and green LED only indicate the behavior of output OUT1.
The behavior of output OUT2 is not indicated.
The 2-point window-teach can be configured either with the control buttons or via the IO-Link interface. Adjustment via
the teach input is not possible.
1-point teach (1 switching point per output)
Switching behavior NO contact
Switching behavior NC contact
2-point window-teach (2 switching points per output)
Switching behavior NO contact
Switching behavior NC contact
Switching function
configured as
First taught object
distance
Second taught object
distance
Output switching behavior
NO (normally open)
NC (normally closed)
Far
Close
Close
Far
D
ead
z
on
e
S
ensor
OUT active
Yellow LED ON
Green LED OFF
OUT not active
Yellow LED OFF
Green LED ON
Distance
Hysteresis
Switching point
Operating range
OUT not active
Yellow LED OFF
Green LED OFF
OUT not active
Yellow LED OFF
Green LED OFF
D
ead
z
on
e
S
ensor
OUT not active
Yellow LED OFF
Green LED ON
OUT active
Yellow LED ON
Green LED OFF
Distance
Hysteresis
Switching point
Operating range
OUT active
Yellow LED ON
Green LED OFF
OUT active
Yellow LED ON
Green LED OFF
Dea
d zon
e
S
ensor
OUT active
Yellow LED ON
Green LED
OFF
OUT not acti
-
ve
Yellow LED
OFF
Green LED
ON
Distance
Hysteresis
Operating range
OUT not active
Yellow LED OFF
Green LED OFF
OUT not active
Yellow LED OFF
Green LED OFF
Hysteresis
OUT not acti
-
ve
Yellow LED
OFF
Green LED
ON
Switching
point 1
Switching
point 2
Dea
d zon
e
S
ensor
OUT active
Yellow LED
ON
Green LED
OFF
OUT not acti
-
ve
Yellow LED
OFF
Green LED
ON
Distance
Hysteresis
Operating range
OUT active
Yellow LED ON
Green LED OFF
OUT active
Yellow LED ON
Green LED OFF
Hysteresis
Switching
point 1
Switching
point 2
OUT active
Yellow LED ON
Green LED OFF
HTU430B
Содержание HTU430B Series
Страница 8: ...HTU430B X3 LT4 M12 03 2019 05 8 HTU430B...