Leuze electronic HTU430B Series Скачать руководство пользователя страница 2

HTU430B-…X3/LT4-M12 - 03

2019/05

2

Technical data

Ultrasonic specifications

HTU430B-3000.X3/…

HTU430B-6000.X3/...

Operating range 

1)

1) At 20°C

300 … 3000mm 

2)

2) Target: 100mm x 100mm plate

600 … 6000mm 

2)

Adjustment range

300 … 3000mm

600 … 6000mm

Ultrasonic frequency

120kHz

75kHz

Typ. opening angle

15°

Resolution of switching output

1mm

Direction of beam

Axial

Accuracy

± 0.5% of end value 

1)

 

Reproducibility

± 0.15% of end value 

1)

 

Switching hysteresis

25mm

50mm

Temperature drift

± 1.5% of end value 

1)

 

Sensor operating modes

IO-Link 

COM2 (38.4kBaud)

SIO

Is supported

Time behavior

Switching frequency

4Hz

1.6Hz

Response time

125ms

380ms

Readiness delay 

< 300ms

Electrical data

Operating voltage U

B 3)

 

3) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

SIO mode: 15 … 30V DC (incl. ± 10% residual ripple),

COM2 mode: 18 … 30V DC (incl. ± 10% residual ripple)

Residual ripple

10% of U

B

Open-circuit current

50mA

Switching output

OUT1:1 x PNP transistor, IO-Link SIO mode, 

OUT2:1 x PNP transistor, configurable

Function (PNP)

2 x NO contact, reversible

Output current

SIO mode: max. 150mA per contact,

COM2 mode: max. 100mA per contact

Switching range adjustment

OUT1: control button 1 or teach input

OUT2: control button 2 or teach input

Changeover NO/NC

OUT1: control button 1 or teach input

OUT2: control button 2 or teach input

Indicators

Yellow LED 

OUT1: object detected

Yellow LED, flashing

Teach-in / teaching error / cable short circuit

Green LED 

Object within the operating range

Green LED flashing

IO-Link communication

Mechanical data 

Housing 

All metal - brass, nickel-plated

Weight 

110g

215g

Ultrasonic transducer

Piezoceramic 

4)

4) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)

Connection type 

M12 connector, 5-pin

Installation position

Any

Environmental data

Ambient temp. (operation/storage) 

-25°C … +70°C/

-40°C … +85°C 

-25°C … +50°C

Protective circuit 

5)

5) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection

1, 2, 3

VDE protection class

III

Degree of protection 

IP 67 and IP 68

Standards applied

EN 60947-5-2

Certifications

UL 508, C22.2 No.14-13 

3)

 

6)

 

7)

6) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7); 

Use tool for buttons

7) Ambient temperature 85°C. Use same voltage supply for all circuits.

Diagrams

HTU430B-3000…-M12

HTU430B-6000...-M12

Notes

Observe intended use!

This product is not a safety 

sensor and is not intended 

as personnel protection.

The product may only be put 

into operation by competent 

persons.

Only use the product in ac

-

cordance with its intended 

use.

-600

-400

-200

0

200

400

600

0

500

1000 1500 2000 2500 3000

y1

y2

Object distance x [mm]

W

idt

of

 the

 s

ou

nd 

cone

 [m

m

]

Typ. response behavior 

(plate 100x100mm)

-600

-400

-200

0

200

400

600

0

500

1000 1500 2000 2500 3000

y1

y2

Object distance x [mm]

W

idth

 y o

f th

e so

un

d co

ne

 [m

m

]

Typ. response behavior 

(rod Ø 27mm)

-1500

-1000

-500

500

1000

1500

-2000

2000

0

1000 2000 3000 4000 5000 6000

y2

y1

0

Object distance x [mm]

Wi

dt

of

 the 

sou

nd

 c

one 

[m

m

]

Typ. response behavior 

(plate 100x100mm)

-1500

-1000

-500

500

1000

1500

-2000

2000

0

1000 2000 3000 4000 5000 6000

y2

y1

0

Object distance x [mm]

Wi

dt

of

 th

so

un

co

ne

 [m

m

]

Typ. response behavior 

(rod Ø 27mm)

Object distance [mm]

Target (fixed):

plate or rod

Sound cone

= f (

,x)

HTU430B

Содержание HTU430B Series

Страница 1: ...design NEW Process data and configuration via IO Link interface NEW Five operating modes scanning synchronous multiplex activation and throughbeam operation 300 3000mm 600 6000mm 15 30 V DC Accessori...

Страница 2: ...Ultrasonic transducer Piezoceramic 4 4 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Installation position Any Environment...

Страница 3: ...X Advanced design 3 Teach button on the sensor Pin assignment of connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset L IO Link communication or push pul...

Страница 4: ...First taught object distance Second taught object distance Output switching behavior NO normally open NC normally closed Far Close Close Far Dead zone Sensor OUT active Yellow LED ON Green LED OFF OU...

Страница 5: ...adjust output OUT2 press button 2 for 7 12s until the yellow and green LED flash alternately at 3Hz 3 Release the teach button to complete the teach event The current object distance has been taught...

Страница 6: ...adapter position Teach GND The current state of output OUT2 is frozen during the teach event 3 The yellow LED flashes at 3Hz and is then ON The current object distance has been taught as the new swit...

Страница 7: ...ughbeam sensor requires 2 sensors which are electrically connected through one line Switching outputs OUT1 OUT2 Switching point 1 2 The switching points can be directly entered as distance value in mm...

Страница 8: ...HTU430B X3 LT4 M12 03 2019 05 8 HTU430B...

Отзывы: