5.2.4
Fastening via clamp brackets
Mounting with the BT-2P40 clamp bracket allows the device to be replaced quickly. A new alignment
can be omitted. The light curtain can be moved in the direction of the groove. Turning, tilting and
pitching are not possible.
5.2.5 Positioning height measurement
Transmitter and receiver should be aligned parallel to each other. The plane of the height and width
light curtains should be perpendicular to the transport direction of the measurement objects. A
deviation significantly reduces the power reserve!
NOTICE
Must be observed!
The maximum object height must not project beyond the top light beam of the HIGH light
curtain!
If the lowest light beam of the HEIGHT light curtain is above the lower edge of the measurement
object, the correct offset of the HEIGHT light curtain must be measured in the measurement scene
and entered in WebConfig, see chapter 7.4.1.
Object height