Leonton EG5-1600-M12XB-110-67 Скачать руководство пользователя страница 3

 

 

FCC Notice

 

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant 
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency 
energy. It may cause harmful interference to radio communications if the equipment is not installed and 
used in accordance with the instructions. However, there is no guarantee that interference will not occur in 
a particular installation. If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

 

 

Reorient or relocate the receiving antenna.

 

 

Increase the separation between the equipment and receiver.

 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.

 

 

Consult the dealer or an experienced radio/TV technician for help.

 

 

Caution: Any changes or modifications not expressly approved by the grantee of this device could void 
the user's authority to operate the equipment.

 

 

Déclaration FCC

 

Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements 
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour fournir 
une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. Cet 
équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé et 
utilisé conformément au manuel d’instruction, peut perturber la réception radio. Cependant, il n’est pas 
garanti que l’équipement ne produira aucune interférence dans une installation particulière. Si cet 
équipement cause des interférences nuisibles à la réception radio ou télévisée, qui peuvent être 
déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à essayer de remédier au problème 
en prenant les mesures suivantes:

 

 

Réorienter ou déplacer l’antenne réceptrice.

 

 

Augmenter la distance entre l’équipement et le récepteur.

 

 

Connecter l’équipement à une prise secteur sur un circuit différent de celui utilisé par le récepteur.

 

 

Consulter le négociant ou un technicien radio/TV expérimenté.

 

 

Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de cet 
appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.

 

 

CE Mark Warning

 

This is a Class-A product. In a domestic environment this product may cause radio interference in which 
case the user may be required to take adequate measures.

 

 

CE Mark Avertissement

 

Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en 
présence d'interférences radio.

 

 

This document is the current official release manual. Please check our website (www.leonton.com) for 
any updated manual or contact us by e-mail ([email protected]).

Содержание EG5-1600-M12XB-110-67

Страница 1: ...EG5 1600 M12XB 110 67 EG5 1600 M12XB 110 T67...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Страница 4: ...l Dimensions 3 Front Panel 4 LED Indicators 5 Ethernet Ports 6 USB Port 7 Console Port 7 Power Inputs 8 Relay Contact and Digital Input 9 Grounding Note 11 Bypass Function 11 Reset to Default 11 MOUNT...

Страница 5: ...of 40 C 70 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X function Embed...

Страница 6: ...de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convertiss...

Страница 7: ...3 HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 1600 M12XB 110 67 series W x H x D is 295mm x 160mm x 101 3mm Figure 2 1 Physical Dimensions...

Страница 8: ...2 2 On the front panel it provides 16 M12 connectors in a polka dot pattern to ensure easier plugging and safer operation The LED indicates various status by different colors and shapes of the light...

Страница 9: ...ent happened after the last reset or reboot Red On 1 System booting 2 Event happened by software setting Red Flashing Firmware Upgrade Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Own...

Страница 10: ...BI_DD 6 BI_DD 7 BI_DC 8 BI_DC Table 2 2 Note and signs represent the polarity of the wires that make up each wire pair Connection of Cables Use the twisted pair cable category 5e or the above cabling...

Страница 11: ...on backup restore M12 connector M12 4 Pin A Coded female Connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Console Port It is a M12 5 Pin A Coded female connector Baud rate 115 200bps 8 N 1 M12 connec...

Страница 12: ...assignment M12 5 Pin K Coded Male Connector Pinouts Function 1 V1 2 V1 3 V2 4 V2 5 GND Table 2 3 Connection of Cables Minimum Wire Gauge 18AWG Please follow the below steps to insert the power wire St...

Страница 13: ...Power 1 or Power 2 was inactive 3 If any one of all PoE ports exceeds 30Watts for PoE models 4 Event happened by software setting Relay is closed under the conditions below 1 No event after reboot 2 N...

Страница 14: ...tage the DI function will be triggered Table 2 5 is shown a detail specification of the digital input Specification Description Level 0 Low 30 8VDC Will trigger DI function active trigger states Level...

Страница 15: ...es loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 5 for example if Switch B has power failure the bypass funct...

Страница 16: ...nded use the M5 screws Step 2 Based on the Figure 3 2 Physical Dimensions which is shown the positions of 4 screw holes on the left and right side of the switch to make 4 screw holes on a wall accordi...

Страница 17: ...elp on how to wire power please refer to the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 4 Prepare the M12 cable for Ethernet connection Step 5 Insert...

Страница 18: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Страница 19: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...