![Leonton EG5-1600-M12XB-110-67 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/leonton/eg5-1600-m12xb-110-67/eg5-1600-m12xb-110-67_hardware-user-manual_1882829014.webp)
10
Digital Input (DI)
The digital input is used for monitoring two external events via an external voltage source. When the voltage
level on digital input pins changes from high voltage to low voltage, the DI function will be triggered. Table
2.5 is shown a detail specification of the digital input.
Specification
Description
Level 0 (Low)
-30~8VDC
Will trigger DI function (active trigger states)
Level 1 (High)
10~30VDC
Normal Status (inactive trigger states)
Nominal input voltage
24VDC
Max. input voltage
30VDC
Nominal input current
5mA (typical)
Max. input current
8mA
Table 2.5:
Specification of DI