Product description
Device features
Ò
19
EDSMDAG EN 2.0
3.2
Device features
Device feature
EMDAG2...
EMDAG3...
EMDAG4...
EMDAG5...
Power range
(Peak Power)
kW
7.5 ... 60
2.8 ... 5.6
2.8 ... 60
7.5 ... 22
DC/AC inverter
2
˘
1
1
DC/DC converter
˘
1
1
˘
Approval acc. to ECE R10
l
l
l
l
Degree of protection
IP6K9K
IP6K9K
IP6K9K
IP6K9K
Cooling
Water / glycol (
^
Mounting type
free
12/24−V voltage for maintaining the
control functionality in the case of
mains failure
l
l
l
l
Digital inputs
4
4
4
4
configurable as analog input
2
2
2
2
configurable as frequency input
2
2
2
˘
Digital outputs
4
4
4
˘
Resolver connection
2
˘
1
˘
Motor temperature monitoring
PT1000, KTY83/110, KTY84/130, thermostat (normally−closed contact)
acc. to DIN44080, PTC acc. to DIN44081
Public CAN
l
l
l
l
Baud rate
kbps
125 ... 500
125 ... 500
125 ... 500
125 ... 500
Private CAN
l
l
l
l
Baud rate
kbps
125 ... 1000
125 ... 1000
125 ... 1000
125 ... 500
Operation in generator mode
(optional)
l
˘
l
l
Loop−through of HV system
l
l
l
˘
Overload cycle at 1.8 × I
rated
10 s
˘
10 s
10 s
Overload cycle at 1.5 × I
rated
60 s
˘
60 s
60 s
Motor speed range
rpm
−32000 ... 32255
˘
−32000 ... 32255 −32000 ... 32255
Technology application
Actuator speed
l
˘
l
l
Switch−off positioning
m
˘
m
˘
Absolute positioning
m
˘
m
˘
l
Included as standard
m
Optionally available
˘
Not available