16.3.2
Basic setting and options
16.3.2.1
Station name and IP configuration
The station name and the IP configuration can be assigned via the IO-Controller. These set-
tings enable the IO-Controller to identify the inverter in the network and manage the data
exchange.
The station name and the IP configuration can also be assigned via the »EASY Starter«:
•
The station name of the inverter must be entered with permissible characters according to
the PROFINET specification.
•
Display of the currently used station name:
•
The IP configuration comprises the assignments of:
•
IP address
•
Subnet mask
•
Gateway address
•
Display of the currently used IP configuration:
Save the station name and the IP configuration in the inverter with mains failure
protection in order that the inverter can be identified via Ethernet if the IO Con-
troller is switched off.
See:
An invalid station name or the assignment of invalid combinations of IP address,
subnet mask and gateway address may prevent a connection to PROFINET.
In case of impermissible settings, the red LED "BUS ERR" is blinking and the
error message "PROFINET: stack initialisation error [0x8192]" is displayed.
Parameter
Address
Name / setting range / [default setting]
Info
0x2381:001
PROFINET settings: IP address
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set IP address
•
A changed value will only be effective after the PROFINET communica-
tion is restarted (
= 1).
0x2381:002
PROFINET settings: Subnet
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set subnet mask
•
A changed value will only be effective after the PROFINET communica-
tion is restarted (
= 1).
0x2381:003
PROFINET settings: Gateway
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set gateway address
•
A changed value will only be effective after the PROFINET communica-
tion is restarted (
= 1).
•
The gateway address is valid if the network address of the IP address
is identical to the gateway address. In this case, no gateway function-
ality is used.
•
DHCP is not supported.
0x2381:004
PROFINET settings: Station name
Set station name
•
A changed value will only be effective after the PROFINET communica-
tion is restarted (
= 1).
0x2381:005
PROFINET settings: I&M1 System designation
Input/output of the I&M1 system designation
•
The default setting is an empty string.
0x2381:006
PROFINET settings: I&M1 Installation site
Input/output of the I&M1 location identification code
•
The default setting is an empty string.
0x2381:007
PROFINET settings: I&M2 Installation date
Input/output of the I&M2 date of installation
•
The default setting is an empty string.
0x2381:008
PROFINET settings: I&M3 additional information
Input/output of the I&M3 additional information
•
The default setting is an empty string.
0x2381:009
PROFINET settings: I&M4 signature code
["000000000000000000000000000000000000000000
0000000000000000000000000000000000000000000
00000000000000000000000"]
Input/output of the I&M4 signature
•
The default setting is an empty string.
Configuring the network
PROFINET
Basic setting and options
358
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......