Technical data
General data and operating conditions
4
l
31
EDKZS3YA200 DE/EN/FR/ES/IT 3.0
4
Technical data
4.1
General data and operating conditions
Conformity and approval
CE
2014/35/EU
Low−Voltage Directive
Approval
UR
UL508
CSA C22.2 No.14
Industrial Control Equipment, Underwriter
Laboratories (File−No. E219022) for USA and Canada
Protection of persons and equipment
Enclosure
EN 60529
IP20
NEMA 250
Protection against
contact to type 1
Insulation resistance
IEC/EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1 1K3 (−25 ... +60 °C)
Transport
IEC/EN 60721−3−2 2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3 3K3 (−10 ... +55 °C)
Current derating at +40 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating 5 %/1000 m
Pollution
EN 61800−5−1
Degree of pollution 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721−3−2 2M2
EN 61800−2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: Acceleration resistant up to 10 m/s
2
200 ... 500 Hz: Acceleration resistant up to 15 m/s
2
Operation
Germanischer
Lloyd
5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: Acceleration resistant up to 0.7 g
IEC/EN 60068−2−6 10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 10 m/s
2
Содержание EZS3 A200 Series
Страница 78: ...Instalaci n el ctrica 6 l 78 EDKZS3YA200 DE EN FR ES IT 3 0...
Страница 98: ...Installazione elettrica 6 l 98 EDKZS3YA200 DE EN FR ES IT 3 0...
Страница 99: ......