14
Implemented CIP™ objects
14.3
Lenze objects
139
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3
Lenze objects
14.3.1
Lenze Class (101 / 0x65)
The "Lenze Class (101 / 0x65)" enables the access to the error responses to EtherNet/IP errors
adjustable in code
.
Class attributes
Instance attributes
Attribute
ID
Service
Name
Data type
Value
1
Get
Revision
UINT
2 (0x0002)
2
Get
Max. Instance
UINT
1 (0x0001)
Attribute
ID
Service
Name
Data type
Value
1
Get
No. of supported Attributes
USINT
6 (0x0006)
2
Get
Attribute List
USINT
1 (0x0001) ... 6 (0x0006)
3
Get / Set Reaction on Idle Mode
USINT
Corresponds to the value in
/
:
• 0 = no response
• 1 = error
• 3 = quick stop by trouble
• 4 = warning locked
• 6 = information
4
Get / Set Reaction on Fault Mode
USINT
Corresponds to the value in
/
:
• 0 = no response
• 1 = error
• 3 = quick stop by trouble
• 4 = warning locked
• 6 = information
5
Get / Set Reaction on Expl. Msg. TO
USINT
Corresponds to the value in
/
:
• 0 = no response
• 1 = error
• 3 = quick stop by trouble
• 4 = warning locked
• 6 = information
6
Get / Set Reaction on I/O Timeout
USINT
/
:
• 0 = no response
• 1 = error
• 3 = quick stop by trouble
• 4 = warning locked