![Lenze E94APNE0 4 Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/lenze/e94apne0-4-series/e94apne0-4-series_mounting-instructions_1882533038.webp)
Technical data
General data and operating conditions
3
38
EDK94PNE36 DE/EN/FR/ES/IT 2.0
3
Technical data
3.1
General data and operating conditions
Supply system data
Supply forms
With earthed neutral Unrestricted use
IT systems
Observe instructions about special measures!
Noise emission
EN 61800-3
Cable-guided: cannot be specified because dependent on the
conditions present in the interconnected system
Radiation: category C3
Noise immunity
EN 61800-3
Category C3
Standards
Conformity
CE
Low-Voltage Directive (73/23/EEC)
Approval
UL 508C
Power Conversion Equipment (file no. 132659)
Protection
Enclosure
EN 60529
IP 20
Not in the wire range of
the terminals on the
motor side
NEMA 250
Protection against contact to
type 1
Insulation resistance
EN 61800-5-1
Overvoltage category III
Derating at and above 2000 m: overvoltage category II
Discharge current
EN 61800-5-1
> 3.5 mA
Observe regulations and
safety instructions!
Environmental conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Power derating at +45 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
Power derating at 1000 ... 4000 m amsl: 5 %/1000 m
Pollution
EN 61800-5-1
Pollution degree 2
Vibration resistance
Germanischer Lloyd General conditions: acceleration resistant up to 0.7 g