5
GHB 13.0001−EN EN 3.0
Key for the overview
View from the front
Pos.
Description
X1
RS232
X5
Digital inputs and outputs / analog inputs and outputs
X6
Slot for multimedia memory card
931EC ˘ View from above
Pos.
Description
X2
Voltage supply
X4.1
X4.2
CAN interfaces
X10
Digital frequency interface
931EP ˘ View from above
Pos.
Description
X2
Voltage supply
X4.1/X4.2
PROFIBUS interface
X10
Digital frequency interface
View from below
Pos.
Description
X3
Motor connection
X7
Resolver input
X8
SinCos encoder input
LED
Colour
State
Note
State
Green
on
The control is correctly supplied by a 24 V control voltage, the drive is ready for operation.
blinking
Data is written on or read from the memory card.
off
No voltage
Power
Yellow
on
The power section is enabled, the motor is supplied with voltage. The drive works with the set
control.
off
The drive does not work, the output stage is inactive.
Error
Red
off
No fault
blinking
Internal drive error
1)
After the cause of the error has been eliminated, you have to acknowledge the error message:
l
Either by using the parameterisation software, or via an edge at DIN9 (controller enable).
l
If no error is active anymore, the LED goes out.
Green
Yellow
Red
on
l
The drive is in the initialisation phase after the control voltage has been switched on.
l
A new firmware is being installed.
1)
Detailed description of the blink codes:
Note!
The light−emitting diode "Error" constantly blinks if a fault is active:
ƒ
It only displays one fault at a time.
ƒ
If several faults are active at the same time, the fault that occured first is displayed.