Technical data
Communication
Controller with CAN bus
17
GHB 13.0001−EN EN 3.0
3.3
Communication
3.3.1
Controller with CAN bus
Area
Values
Communication profile
DS 301, DSP 402
Communication medium
RS232
Network topology
Without repeater: line / with repeaters: line or tree
CAN node
Slave
Baud rate (in kbps)
10, 20, 50, 100, 125, 250, 500
Maximum cable length per bus
segment
1200 m (dependent on baud rate and cable type used)
Bus connection
RJ45
3.3.2
Controller with PROFIBUS
Area
Values
Communication profile
(DIN 19245 part 1 and part 3)
PROFIBUS−DP−V0
Communication medium
RS485
Drive profile
PROFIdrive
Network topology
Without repeater: line / with repeaters: line or tree
PROFIBUS−DP station
Slave
Baud rate [kbps]
9.6 ... 12000
Maximum cable length per bus
segment
1200 m (dependent on the baud rate and cable type used)
Bus connection X4.1, X4.2
9−pin Sub−D socket