Other application examples
MA82ZBU 1.0
- 5 -
Starting/stopping (CINH) with the function module Standard-I/O
Terminal assignment
X3/20
Brown wire
DC 20 V
X3/28
White wire
Start/stop
Green wire = not used
Appropriate insulation!
Switch/potentiometer unit
ó
Wire bridge
Wiring for start/stop through switch
CINH
Controller inhibit
/CINH
Controller enable
Starting/stopping (CINH) with the function module Application-I/O
Terminal assignment
X3/20
Brown wire
DC 20 V
X3/28
White wire
Start/stop
Green wire = not used
Appropriate insulation!
Switch/potentiometer unit
Wiring for start/stop through switch
CINH
Controller inhibit
/CINH
Controller enable
Instead of using X3/28 also digital input (X3/E1 ... X3/E6) can be connected
and thus different digital functions, e.g. JOG1 on E1, can be activated.
Show/Hide Bookmarks