Mechanical installation
Important notes
3
EDK82ZM113−001 DE/EN/FR 1.1
33
l
H1_MechINS−Montage_Var_E82ZM−001
3
Mechanical installation
Important notes
ƒ The mounting location must always fulfill the operating conditions specified in the
Technical data. (
29). If necessary, take additional measures.
ƒ The mounting plate of the control cabinet must be:
– electrically conductive
– free of lacquer
ƒ The mechanical connections must always be ensured.
ƒ The motor interference suppression module can be mounted in two different ways:
– Standard mounting: the standard device is mounted to the interference
suppression module.
– Mounting variant: the standard device is mounted to the left side of the
interference suppression module.
The standard devices E82xV552Kx, E82xV752Kx and E82xV113K4 are of greater width
than the interference suppression module. Here, the mounting variant must be applied.