![Lenz Digital Plus LS150 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/lenz/digital-plus-ls150/digital-plus-ls150_information_1881904028.webp)
28
If the address of an output is reset, the pulse duration set during a
previous setting procedure will remain unchanged.
Resetting the decoder
To reset the decoder to the ex-works setting, proceed as follows:
1.
Interrupt the AC voltage supply to the LS150 (You can switch off the
transformer at the mains).
2.
Press the key on the LS150 and keep it pressed down.
3.
Switch the AC voltage back on again.
4.
Proceed as if you wanted to switch the chosen point and press the
corresponding key of the digital system.
5.
Release the key.
The LS150 is now reset to the point addresses 1 – 6 and the shortest pulse
duration (100ms). Afterwards, the decoder will complete a test during which each
output is activated one after another. If you have connected point drives, these
will be activated briefly after each other.