18
Information LRB08
7.1 Ex-works, CVs are set as follows:
CV
Meaning
Value
1
Address
65
7
Decoder-ID
103 (*)
8
Manufacturer's ID
99 (*)
40
Delay
50
128
firmware version
(*)
CVs other than those listed here are not supported. CVs marked (*) can be read
out but not altered.
7.2 Programming the address and delay times
You can choose between 2 different procedures:
3.
Programming at the programming output of your digital system. This
procedure is used before installation. You can set the address and input
features.
4.
Programming in operational mode. This procedure is possible only if the
LRB08 is already installed on your layout. You can only change the address.
7.2.1
Programming at the programming output
Connect terminals J,K of the LRB08 to the programming output of the Digital plus
system (terminals P and Q). The Figure below illustrates the connection to the
command station LZV100. The connection to the command station LZV100/LZ100
is made in the same way.
Programming the address
Select CV1 as the CV to be altered, then program the desired address. Please
bear in mind the permissible value range of 1 to 128.
Programming the delay times
The procedure is the same as described under 'Programming the address'. Now
select CV40 instead of CV1 for the address to set the delay time for all eight track
sections. Then program the value for the desired delay time into CV40.