13.2.5 Reading out CVs using the LRC120 address display
It is possible to read out CV values via PoM during operation.
Requirements:
use of a RailCom-capable locomotive decoder
the locomotive is located in a track section monitored by the
LRC120 address display
RailCom transmission is enabled in the decoder
Information on how to connect the LRC120 address display as well as
the settings of RailCom-capable locomotive decoders can be found in
the respective operating manuals.
Proceed as follows:
Action
Display
Explanation
Call up the locomotive whose settings you
want to change using PoM.
Move the locomotive whose CVs you want to read out using PoM to the
track section monitored by the LRC120 address display. The address
display now shows the address of the locomotive.
Press the 'M' key. You are offered the option
last used (in this example the multiple
traction).
Turn the rotary knob until "Programmieren
während des Betriebs PoM/Programming in
operational mode" is displayed.
Press the rotary knob to select the option
"PoM". You are asked to enter the CV that
you want to change using PoM.
Use the keys to enter the number of the CV
…
… and press the rotary knob to complete the
entry process.