Locomotive decoder LE010XF
9
DIGITAL plus
CV
Description
Range
Setting
29
bit 0
(1)
locomotive direction:
Locomotive’s relative direction: This bit sets
the direction the locomotive will move when
told to move forward in digital mode.
0 = locomotive’s direction is normal
1 = locomotive’s direction is inverted
0,1
0
[1]
bit 1
(2)
Headlight mode:
0 = Operation with 14 or 27 speed step
systems. This setting is selected when the
locomotive decoder is used with any Digital
system that does not support 28 speed step
mode. If the headlights turn on and off as
the speed is increased, the command station
is configured for 28 speed step mode, and
the decoder is in 14 speed step mode.
1 = Operation with 28, 55 or 128 speed
steps. If you use this setting, the Command
Station must also be configured to use 28
speed step mode or 128 speed step mode
for the decoder's address, otherwise the
headlights can not be controlled.
0,1
1
[2]
bit 2
(3)
Usage on conventional DC layouts:
0 = locomotive operates in digital mode only
1 = locomotive can operate on either
conventional DC and on DCC
0,1
1
[4]
bit 3
always 0
0
0
bit 4
(5)
Speed Curve Selection:
0 = factory pre-set speed curve is used
1 = user defined speed curve is used.
Please enter the appropriate values into CV
67 to 94 before setting this bit.
0,1
0
[16]
bit 5
(6)
Extended Addressing:
0= Normal addressing
1=Two Byte extended addressing
0-1
0
[32]
bit 6
bit 7
always 0
0
0
50
Decoder Configuration, byte 2:
Similar to CV 29, but used to set other properties
1
bit 0
(1)
Back EMF Control
If set back emf control is active
0,1
1
bits
2-7
not used