Locomotive decoder LE230
DIGITAL plus
CV
R
e
g
Description
Range
Factory
setting
bit 2
speed step mode:
0 Operation with 14 or 27 speed steps.
This setting is selected when the locomotive decoder
is used with a software below version 2.0, ROCO-
Digital, LGB-Digital, Arnold Digital and with all
other Digital systems that do not support the 28
speed step mode.
1 Operation with 28 speed steps.
This setting is selected when the locomotive decoder
is used with a Command Station with software
version 2.0 or higher. The Command Station has to
be set to 28 speed step mode for the decoder address,
if you are using this setting!
Other Digital systems supporting the 28 speed step
mode can use the decoder in this setting.
0,1
0
bit 3
Usage on conventional DC layouts:
0 locomotive operates in digital mode only
1 locomotive can operate in both conventional DC
and digital mode.
0,1
1
bit 4
always 0
0
0
bit 5
speed curve:
0 factory pre-set speed curve is used
1 user defined speed curve is used. Please enter the
appropriate values into CV 67 to 80 before setting
this bit.
0,1
0
bit 6
Extended Addressing
0= Normal addressing
1=Two Byte extended addressing
0-1
0
bit 7
bit 8
always 0
0
0
30
-
Decoder Error Information
bit 1
Motor Short
If set short between motor and track
0,1
0
bit 2
Front Headlight Short
If set the front headlight is shorted
0,1
0
bit 3
Rear Headlight Short
If set the rear headlight is shorted
0,1
0