Locomotive decoder LE230
11
DIGITAL plus
CV
R
e
g
Description
Range
Factory
setting
-
5
CV29 when the page/pointer register has a value of 1
or value of CV pointed to by Register 6 when register
6 is being used as a pointer register
0-63
4
-
6
Page/Pointer Register:
Used during programming for paging or indexing
0-127
1
7
7
Version Number:
This location stores the version number of the decoder.
This location is read only.
-
51
8
8
Manufacturers Identification:
This value is the manufacturer ID of the decoder, (Lenz
=99). This location is read only.
-
99
9
-
EMF Frequency
Allows you to adjust the pulse rate frequency for finer
motor control
0-15
4
17
-
Extended Address High Byte
192-
231
0
18
-
Extended Address Low Byte
The two byte address if used is contained in CV17+18
0-255
0
19
-
Consist Address
The advanced consist address if used is stored in CV19
0-255
0
29
*5
Decoder Configuration, Byte 1:
Several decoder properties are set with this byte. Changes
are best done in binary mode (see the information for the
Hand Held LH100). The detailed properties are:
0-63
4
bit 1
locomotive direction:
0 normal: locomotive moves forward when the
arrow on the Hand Held points up.
1 inverted: locomotive moves forward when the
arrow on the Hand Held points down.
0,1
0