-4-
IMPORTANT USER INSTRUCTION & SAFETY NOTICE.
KEEP SAFE!
ELECTRICAL NOTICE
In order to ensure proper use, a separate
120v 60HZ 15amp(per dedicated outlet)
GFCI protected grounded circuit must be used to supply power to each pedicure spa.
Failure to do so renders the Limited Warranty void.
**PEDICURE SPAS outside the US must be in accordance with the respective country’s
rules and regulations. For example, if installed in Canada, the pedicure spa must be in
accordance with the Canadian Electrical Code Part1.
GROUNDING AND GFCI NOTICE
STOP! PLEASE READ PRIOR TO INSTALLATION AND USE!
When using electrical products, basic precautions should be followed:
1. Risk of electrical shock. Connect the pedicure spa only to a circuit protected by a ground-fault circuit-inter-
rupter.GFCI)
2. Every EMPRESS Pedicure Spa must be installed by your local, licensed plumber and licensed electrician
to install your new spa. Installation MUST be in compliance with all local and state building codes.
3. Your pedicure spa cannot operate efficiently or safely unless it is provided with adequate electrical power,
sufficient water pressure, proper water temperature, and required drainage capabilities.
4. Contact your local building inspector for information and local code compliance procedure that need to be
followed when having your new pedicure spa installed.
5. Subsequent inspections and approvals that may be required are the responsibility of the purchaser.
STOP! PLEASE READ PRIOR TO INSTALLATION AND USE!
TO REDUCE THE RISK OF BURNS, ELECTRIC SHOCK, FIRE OR INJURY:
1. Only authorized operators are permitted to use the pedicure spa.
2. If the pedicure spa has a damaged cord or plug, do not use.
3. Keep all electrical cords away from heated surfaces.
4. Do not operate outdoors.
5. You are responsible to ensure that all plumbing connections meet national, state and local code.
6. Shut-off valves are strongly recommended.
7. The water temperature should be adjusted accordingly.
Shipment Inspection
Examine the components immediately upon arrival to make sure no damages to the pedicure spa base and
chair during the shipment. It is very important that you notify the driver directly and notation should be on the
face of the freight bill or bill of lading of any damage. Failure to note damage on the bill of lading may prevent
any claims you may have against the carrier.
If concealed or damage is found, you MUST notify the carrier at once and request an inspection. DO NOT DIS-
CARD THE SHIPPING CARTON If receiver sign the carrier clean receipt of goods that have been damaged in
transit .Do so at your own risk and expense.
Please print this page for your review and reminder.
SAFETY
INSTRUCTION
Important Installation Considerations
Electrical Service
110V, 60Hz, 15Amp GFCI protected grounded circuit MUST be used to supply power each individual
pedicure spa. And the main circuit breaker MUST be at 25Amp. For maximum of two units per each
electrical outlet.
Water Supply
All plumbing connections must conform to local, state, federal codes.
Water supply to the spa should be provided with adequate water pressure and water temperature.
Water Pressure
To fill the basin correctly up to level, Normal water pressure of 30 to 80 P.S.I is required.
Water temperature
The hot water supply temperature must not exceed 140 . Adjust your hot water accordingly. For hot
and cold water supply fittings and drain fittings location, see drain diagram .Carefully connect the water
supply line to the appropriate fittings located on the rear of the pedicure spa.
Pressure / Temperature
Maximum Pressure: 150 psi (10 bars)
Minimum Pressure: 10 psi (69kPa)
Working Temperature: 33F to 140F constant; intermittent to 180f
(0.6C to 60C sustained; intermittent to 82.2C)
Recommended Flow: 1.5gpm .
UL LISTED / CE CERTIFIED
Compliance with following Code (s): Uniform Plumbing Code, National Plumbing Code of Canada
and international Plumbing Code. Also, Compliance with following Standard (s): ASME A112.18.3M /
A112.18.1M, CSA B125, NSF /ANSI 61/372
All EMPRESS USA products has been investigated for compliance with the requirements for water
retention for Whirlpool bathtub appliances contained in ASME / ANSI A122.19.7M(1995), CSA C22.2
No. 68-69
ANSI - American National Institute, ASME - American Society of Mechanical Engineers, CSA - Canadian
Standard Association IAPMO - International Association of Plumbing and Mechanical Officials, UL -
Underwriters Laboratory
** Back flow Protection Device
Due to Town and / or State requirement/s are varies in building code, if the Town and / or State requires
specific Vacuum Breaker, As the Plumber MUST provide Vacuum Breaker according to building code
Installation Summary
A licensed plumber / Electrician MUST install the Pedicure Spa conform and comply with local,State
and Federal building code. where applicable.
Note: Failure to comply with federal, state, or local codes and ordinances will result in warranty
being nullified and void.
Drain Facilities
The pedicure spa Drain must meet local plumbing codes.
Check valve for Drain (not Provided) Must
be installed by a licensed plumber.
Also Pedicure spa must be securely fasten to the floor.
Please print this page for your review and reminder.
SAFETY
INSTRUCTION
(Utility Valves)
Check and