-20-
WARNING: DO NOT RUN DRY, BASIN MUST FILLED WITH WATER TO LEVEL INDICATOR.
CAUTION: MAGNETIC JET COVER ASSEMBLY MUST ALIGN WITH DISCHARGE PORT
POSITIONED AT 3/9 O’CLOCK
.
When Ready to use,
MAKE
sure jet cover is positioned at 3/9 O’clock for proper whirlpool
action in the basin. If jet cover is not align at 3/9 O’clock, water will splash outside of the
basin.
Proper way to use Magnetic Jet System:
1. Fill the water to water level indicator.
2. Hold Magnetic Jet firmly to bring closer to the round magnetic filed and do not release the Magnetic Jet prematurely or
this will cause impacts on the jet cover and the round magnetic field(housing) shortening the life expectancy of the jet cover.
When the jet cover nears the round magnetic field, place jet cover onto the four dimple area (see diagram). The jet cover
must align with discharge ports positioned at 3/9 O’clock.
3. When finished with client, DO NOT remove Magnetic Jet until motor is fully stopped.
4. When motor is fully stopped, remove Magnetic Jet cover from the motor and remove jet cover and impeller for sanitation.
Motor
Round Magnetic Field (housing)
Magnetic
Jet Base
Magnetic
Impeller
Magnetic
Whirlpool Jet Cover
Bottom View of
Magnetic Jet Base
How to USE Magnetic Jet!
a. Automatic spa fills with intelligent and reliable level sensor.
b. Time delay setting
c. Dual switched outlets/ Control box
d. Dual continuous outlets
e. Single drain pump controlled outlet with 3 minute timer (If drain pump requested as an option)
f. Heavy duty water valve
g. Operated in automatic or manual mode
i. Built in LED light power supply
j. Audible overflow warning in manual fill mode
J&A
USA
iFill-Auto
Auto Fill System
(Optional)
Feature & Operation
Dura Jet III Built - in
Electrodes Water Sensor
Press iFIll - Auto to start fill the basin and
once reaches water level
Whirlpool/light will be activated.
Manual On/Off Water
Manual On/Off Switch
for Jet & Light
Time Delay Setting
Power On Indicator
Continuous Outlet (2 Amp)
ALL WIRES ARE INDICATED AS IT SHOWN
Drain Air Switch
Key Pad
Level Sensor
water Valve
12 AC Light
Auto Fill
Delay
Setting
Key Pad
Level
Sensor
Water
Valve
12 VAC
Light
Cont (2A)
iFill Delay
Setting
Power Cord
Power
LED
Drain (2A)
Jet (2A)
Light (2A)
Power Cord
Cont (2A)
INSTRUCTION
Water faucet MUSt be ON and desirable
temperature must be set with faucet handle before
using AUTO-FIll System.
1- Press the iFill - Auto button will fill the basin with
water automatically.
Water valve will shutoff when water level is above the
sensor.
2- Process the JET button will turn On/Off the JET and
LED light manually.
3- Processing the valve button will turn On/Off the
water manually.
OPTIONAL
AUT
O
FILL
OPTIONAL
MOT
OR