40
Lenovo ThinkSystem NE2552E Flex Switch: Installation Guide
Enabling Management Through Data Ports
To
access
and
manage
the
switch
through
external
interfaces,
you
must
enable
the
data
(non
‐
management)
ports
and
the
ability
to
manage
the
switch
through
them.
Use
the
information
in
the
following
table
to
configure
your
ports.
To
enable
management
through
data
ports,
complete
the
following
steps:
1.
Log
on
to
the
CMM
CLI
as
described
in
the
CMM
documentation.
If
necessary,
obtain
the
IP
address
of
the
CMM
from
your
system
administrator.
2.
Set
the
environment
to
the
bay
where
you
installed
the
switch:
3.
Execute
the
ifconfig
command
to
enable
data
ports
and
external
management:
You
can
now
manage
the
switch
using
its
data
ports
or
external
management
port.
Note:
“External
management”
refers
to
means
other
than
by
the
CMM.
To
externally
manage
the
switch,
additional
IP
interfaces
must
be
configured.
For
more
information
see
the
Application
Guide
for
your
specific
switch
and
its
installed
firmware.
Data Ports
(
-ep
option)
External Mgmt
(
-em
option)
Description
Disabled
Disabled
The
switch
must
be
managed
through
the
CMM.
No
traffic
is
allowed
on
internal
or
external
switch
ports.
Enabled
Disabled
The
switch
must
be
managed
through
the
CMM.
Data
traffic
is
allowed
on
internal
and
external
switch
ports.
Disabled
Enabled
The
switch
can
be
managed
through
the
CMM
or
a
compute
node.
No
traffic
is
allowed
on
internal
or
external
switch
ports.
Enabled
Enabled
The
switch
can
be
manage
through
the
CMM,
a
compute
node,
or
a
management
station
that
is
connected
through
the
swtich.
Data
traffic
is
allowed
on
internal
and
external
switch
ports.
system>
env -T system:switch[1]
ifconfig -ep enabled -em enabled