Message/Symptom
FRU/Action
Non-system disk or disk error-type message
with a known-good diagnostic diskette.
1.
Diskette Drive
2.
System Board
3.
Diskette Drive Cable
Other display symptoms not listed above
(including blank or illegible display)
1.
Display
2.
System Board
Power-on indicator or hard disk drive in-use
light not on, but computer works correctly
1.
Power switch/LED assembly
2.
System Board
Printer problems
1.
Printer
2.
System Board
Program loads from the hard disk with a
known-good diagnostics diskette in the first
3.5-inch diskette drive
1.
Run Setup
and check Startup sequence.
2.
Diskette Drive
3.
Diskette Drive Cable
4.
System Board
5.
Power Supply
RPL computer cannot access programs from
its own hard disk.
1.
If network administrator is using
LCCM Hybrid RPL, check startup
sequence:
a.
First device - network
b.
Second device - hard disk
2.
Hard disk drive
RPL computer does not RPL from server
1.
Check startup sequence
2.
Check the network adapter LED status
Serial or parallel port device failure (system
board port)
1.
External Device Self-Test OK?
2.
External Device
3.
Cable
4.
System Board
Serial or parallel port device failure (adapter
port)
1.
External Device Self-Test OK?
2.
External Device
3.
Cable
4.
Alternate Adapter
5.
System Board
Some or all keys on the keyboard do not
work
1.
Keyboard
2.
Keyboard Cable
3.
System Board
Undetermined problems
1.
Power-off the computer.
2.
Remove or disconnect the following components (if installed) one at a time.
a.
External devices (modem, printer, or mouse)
b.
Any adapters
c.
Memory modules
d.
Extended video memory
86
Hardware Maintenance Manual
Содержание THINKSTATION D10
Страница 1: ......
Страница 2: ......
Страница 3: ...ThinkStation Hardware Maintenance Manual ...
Страница 17: ...Chapter 2 Safety information 11 ...
Страница 18: ...12 Hardware Maintenance Manual ...
Страница 19: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 Chapter 2 Safety information 13 ...
Страница 23: ...Chapter 2 Safety information 17 ...
Страница 24: ...1 2 18 Hardware Maintenance Manual ...
Страница 25: ...Chapter 2 Safety information 19 ...
Страница 26: ...1 2 20 Hardware Maintenance Manual ...
Страница 33: ...Chapter 2 Safety information 27 ...
Страница 34: ...28 Hardware Maintenance Manual ...
Страница 35: ...1 2 Chapter 2 Safety information 29 ...
Страница 39: ...Chapter 2 Safety information 33 ...
Страница 40: ...1 2 34 Hardware Maintenance Manual ...
Страница 44: ...38 Hardware Maintenance Manual ...
Страница 54: ...48 Hardware Maintenance Manual ...
Страница 58: ...52 Hardware Maintenance Manual ...
Страница 64: ...58 Hardware Maintenance Manual ...
Страница 94: ...88 Hardware Maintenance Manual ...
Страница 103: ...Chapter 9 Replacing FRUs types 6423 and 6483 97 ...
Страница 106: ...100 Hardware Maintenance Manual ...
Страница 130: ...124 Hardware Maintenance Manual ...
Страница 140: ...134 Hardware Maintenance Manual ...
Страница 158: ...8 Go to Completing the FRU replacement on page 158 152 Hardware Maintenance Manual ...
Страница 161: ...6 Go to Completing the FRU replacement on page 158 Chapter 10 Replacing FRUs types 6427 and 6493 155 ...
Страница 247: ......
Страница 248: ...Part Number 43C9807 Printed in USA 1P P N 43C9807 ...