1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 87.
3. Lay the server on its side for easier operation.
4. If a PCI card bracket assembly is installed in your server, remove the PCI card bracket assembly. See
“Removing and reinstalling the PCI card bracket assembly” on page 91.
5. Locate an appropriate PCI card slot on the system board. See “System board components” on page
45 to identify the different types of PCI card slots in your server.
6. Remove the PCI card slot bracket by removing the screw that secures the metal bracket and then lifting
the bracket out of the chassis. Store the PCI card slot bracket in the event that you later remove the PCI
card and need the bracket to cover the place.
Note:
Carefully place the removed screw aside. You will need the screw later to secure the PCI card in
place.
Figure 46. Removing a PCI card slot bracket
7. Touch the static-protective package that contains the new PCI card to any unpainted surface on the
outside of the server. Then, take the new PCI card out of the package.
Note:
Carefully handle the PCI card by its edges.
Installing, removing, or replacing hardware
99
Содержание ThinkServer TS430 0387
Страница 1: ...ThinkServer TS430 User Guide Machine Types 0387 0388 0389 0390 0391 0392 0393 and 0441 ...
Страница 18: ...6 ThinkServer TS430 User Guide ...
Страница 66: ...54 ThinkServer TS430 User Guide ...
Страница 96: ...84 ThinkServer TS430 User Guide ...
Страница 186: ...174 ThinkServer TS430 User Guide ...
Страница 194: ...182 ThinkServer TS430 User Guide ...
Страница 198: ...186 ThinkServer TS430 User Guide ...
Страница 218: ...206 ThinkServer TS430 User Guide ...
Страница 219: ......
Страница 220: ......