Page 74
MegaRAID SAS Software User Guide
Chapter 4: WebBIOS Configuration Utility
|
Creating a Storage Configuration
Figure 36:
WebBIOS Virtual Drive Definition Screen
7. Change the virtual drive options from the defaults listed on the screen as needed.
Here are brief explanations of the virtual drive options:
—
RAID Level:
The drop-down menu lists the possible RAID levels for the virtual
drive. Select RAID 1.
—
Strip Size:
The strip size is the portion of a stripe that resides on a single drive in
the drive group. The stripe consists of the data segments that the RAID
controller writes across multiple drives, not including parity drives. For example,
consider a stripe that contains 64 KB of drive space and has 16 KB of data
residing on each drive in the stripe. In this case, the stripe size is 64 KB and the
strip size is 16 KB. You can set the strip size to 8, 16, 32, 64, 128, 256, 512, and
1024 KB. A larger strip size produces higher read performance. If your computer
regularly performs random read requests, choose a smaller strip size. The default
is 64 KB.
—
Access Policy:
Select the type of data access that is allowed for this virtual drive:
RW
:
Allow read/write access. This is the default.
Read Only
: Allow read-only access.
Blocked
: Do not allow access.
—
Read Policy:
Specify the read policy for this virtual drive:
Normal
:
This option disables the read ahead capability. This is the default.
Ahead:
This option enables read ahead capability, which allows the controller to
read sequentially ahead of requested data and to store the additional data in
cache memory, anticipating that the data will be needed soon. This speeds up
reads for sequential data, but there is little improvement when accessing
random data.
Содержание ThinkServer RD330
Страница 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Страница 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Страница 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Страница 52: ...Page 52 MegaRAID SAS Software User Guide Chapter 3 SafeStore Disk Encryption Instant Secure Erase ...
Страница 226: ...Page 226 MegaRAID SAS Software User Guide Chapter 5 MegaRAID Command Tool Miscellaneous Options ...
Страница 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Страница 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Страница 390: ...Page 390 MegaRAID SAS Software User Guide Appendix B MegaCLI Error Messages Error Messages and Descriptions ...
Страница 400: ......
Страница 401: ......