Page 263
MegaRAID SAS Software User Guide
Chapter 8: Configuration
|
Creating a New Storage Configuration
Disk cache policy:
Select a cache setting for this drive:
—
Enabled
: Enable the disk cache.
—
Disable
d: Disable the disk cache.
—
Unchanged
: (the default) Leave the current disk cache policy unchanged.
8.1.2
Optimum Controller settings
for CacheCade
Write Policy: Write Back
IO Policy: Cached IO
Read Policy: No Read Ahead
Stripe Size: 64 KB
8.1.3
Optimum Controller settings
for FastPath
Write Policy: Write Through
IO Policy: Direct IO
Read Policy: No Read Ahead
Stripe Size: 64 KB
8.1.4
Creating a Virtual Drive Using
Simple Configuration
Simple configuration is the quickest and easiest way to create a new storage
configuration. When you select simple configuration mode, the system creates the best
configuration possible using the available drives.
NOTE:
You cannot created spanned drives using the simple configuration procedure.
To create spanned drives, use the advanced configuration procedure described in
Section 8.1.5,
Creating a Virtual Drive Using Advanced Configuration
.
Follow these steps to create a new storage configuration in simple configuration mode.
1. Perform either of the following steps:
a. Right-click the controller node in the device tree in the left frame of the
MegaRAID Storage Manager window and select
Create Virtual Drive
.
b. Select the controller node and select
Go To>Controller>Create Virtual Drive
in
the menu bar, as shown in
Figure 141
.
Содержание ThinkServer RD330
Страница 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Страница 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Страница 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Страница 52: ...Page 52 MegaRAID SAS Software User Guide Chapter 3 SafeStore Disk Encryption Instant Secure Erase ...
Страница 226: ...Page 226 MegaRAID SAS Software User Guide Chapter 5 MegaRAID Command Tool Miscellaneous Options ...
Страница 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Страница 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Страница 390: ...Page 390 MegaRAID SAS Software User Guide Appendix B MegaCLI Error Messages Error Messages and Descriptions ...
Страница 400: ......
Страница 401: ......