Page 31
MegaRAID SAS Software User Guide
Chapter 2: Introduction to RAID
|
RAID Levels
2.4.17
Virtual Drive States
The virtual drive states are described in
Table 5
.
2.4.18
Beep Codes
An alarm sounds on the MegaRAID controller when a virtual drive changes from an
optimal state to another state, when a hot spare rebuilds, and for test purposes.
2.4.19
Enclosure Management
Enclosure management is the intelligent monitoring of the disk subsystem by software
and/or hardware. The disk subsystem can be part of the host computer or can reside in
an external disk enclosure. Enclosure management helps you stay informed of events
in the disk subsystem, such as a drive or power supply failure. Enclosure management
increases the fault tolerance of the disk subsystem.
2.5
RAID Levels
The RAID controller supports RAID levels 0, 00, 1, 5, 6, 10, 50, and 60. The supported
RAID levels are summarized in the following section.
In addition, it supports independent drives (configured as RAID 0 and RAID 00.) The
following sections describe the RAID levels in detail.
Table 5:
Virtual Drive States
State
Description
Optimal
The virtual drive operating condition is good. All configured drives are
online.
Degraded
The virtual drive operating condition is not optimal. One of the configured
drives has failed or is offline.
Partial Degraded
The operating condition in a RAID 6 virtual drive is not optimal. One of the
configured drives has failed or is offline. RAID 6 can tolerate up to two drive
failures.
Failed
The virtual drive has failed.
Offline
The virtual drive is not available to the RAID controller.
Table 6:
Beep Codes, Events, and Virtual Drive States
Event
Virtual Drive State
Beep Code
RAID 0 virtual drive loses 1 or more
virtual drives
Offline
3 seconds on and 1 second off
RAID 1 loses a mirror drive
Degraded
1 second on and 1 second off
RAID 1 loses both drives
Offline
3 seconds on and 1 second off
RAID 5 loses 1 drive
Degraded
1 second on and 1 second off
RAID 5 loses 2 or more drives
Offline
3 seconds on and 1 second off
RAID 6 loses 1 drive
Partially
Degraded
1 second on and 1 second off
RAID 6 loses 2 drives
Degraded
1 second on and 1 second off
RAID 6 loses more than 2 drives
Offline
3 seconds on and 1 second off
A hot spare completes the rebuild
process and is brought into a drive
group
N/A
1 second on and 3 seconds off
Содержание ThinkServer RD330
Страница 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Страница 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Страница 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Страница 52: ...Page 52 MegaRAID SAS Software User Guide Chapter 3 SafeStore Disk Encryption Instant Secure Erase ...
Страница 226: ...Page 226 MegaRAID SAS Software User Guide Chapter 5 MegaRAID Command Tool Miscellaneous Options ...
Страница 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Страница 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Страница 390: ...Page 390 MegaRAID SAS Software User Guide Appendix B MegaCLI Error Messages Error Messages and Descriptions ...
Страница 400: ......
Страница 401: ......