To
run
ServeRAID
Manager
in
Startable
CD
mode,
turn
on
the
server;
then,
insert
the
CD
into
the
CD-RW/DVD
drive.
If
ServeRAID
Manager
detects
an
unconfigured
controller
and
ready
drives,
the
Configuration
wizard
starts.
In
the
Configuration
wizard,
you
can
select
express
configuration
or
custom
configuration.
Express
configuration
automatically
configures
the
controller
by
grouping
the
first
two
physical
drives
in
the
ServeRAID
Manager
tree
into
an
array
and
creating
a
RAID
level-1
logical
drive.
If
you
select
custom
configuration,
you
can
select
the
two
physical
drives
that
you
want
to
group
into
an
array
and
create
a
hot-spare
drive.
Using
express
configuration:
To
use
express
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
Click
Express
configuration
.
3.
Click
Next.
4.
In
the
“Configuration
summary”
window,
review
the
information.
To
change
the
configuration,
click
Modify
arrays
.
5.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
6.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD-RW/DVD
drive.
7.
Restart
the
server.
Using
custom
configuration:
To
use
custom
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
Click
Custom
configuration
.
3.
Click
Next
.
4.
In
the
“Create
arrays”
window,
from
the
list
of
ready
drives,
select
the
drives
that
you
want
to
group
into
the
array.
5.
Click
the
(Add
selected
drives)
icon
to
add
the
drives
to
the
array.
6.
If
you
want
to
configure
a
hot-spare
drive,
complete
the
following
steps:
a.
Click
the
Spares
tab.
b.
Select
the
physical
drive
that
you
want
to
designate
as
the
hot-spare
drive,
and
click
the
(Add
selected
drives)
icon.
7.
Click
Next
.
8.
Review
the
information
in
the
“Configuration
summary”
window.
To
change
the
configuration,
click
Back
.
9.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
10.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD-RW/DVD
drive.
11.
Restart
the
server.
Viewing
the
configuration
You
can
use
ServeRAID
Manager
to
view
information
about
RAID
controllers
and
the
RAID
subsystem
(such
as
arrays,
logical
drives,
hot-spare
drives,
and
physical
46
ThinkServer
RD120
Types
6444,
6445,
6446,
and
6447:
Installation
Guide
Содержание ThinkServer RD120 Type 6444
Страница 1: ...ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 48: ...34 ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 74: ...60 ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 98: ...84 ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 110: ...96 ThinkServer RD120 Types 6444 6445 6446 and 6447 Installation Guide ...
Страница 111: ......
Страница 112: ...Part Number 46U0862 Printed in USA 1P P N 46U0862 ...